Zobrazeno 1 - 10
of 13
pro vyhledávání: '"Bouclier, Roger"'
Autor:
Bouclier, Roger, Boimska, B, Capéans-Garrido, M, Dominik, Wojciech, Hoch, Michael, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, Sharma, Abhishek
The discharge problem in MSGCs reported by several groups can seriously affect the safety of operation of these detectors. In this note we describe recent short medium term measurements giving a more realistic assessment of the problem.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::32c089e74ce4a03275502b8cf61bdf8f
http://cds.cern.ch/record/687052
http://cds.cern.ch/record/687052
Autor:
Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Claes, S, Hoch, Michael, Million, Gilbert, Ropelewski, Leszek, Sharma, Abhishek, Shekhtman, L I, Van Doninck, Walter, Van Lancker, Luc
The forward tracker of the CMS experiment at CERN will consist of a large number of MicroStrip Gas Chambers ( MSGCs), expected to operate for several years in the high luminosity environment of LHC with an accumulated dose rate of ~ 10 mC/yr per cm o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::f7dec8ccc754462636296bbf35e0ba54
http://cds.cern.ch/record/687352
http://cds.cern.ch/record/687352
Autor:
Boimska, B, Bouclier, Roger, Capéans-Garrido, M, Dominik, Wojciech, Hoch, Michael, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, Sharma, Abhishek
Microstrip gas chambers are highly performing in terms of stable operation at high rates and fluxes of minimum ionizing particles. They are manufactured on thin glass ( D-263) coated with a thin diamond-like layer by Chemical Vapor Deposition ( CVD)
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::20f625afffe23fe402c449e55eca4ad7
http://cds.cern.ch/record/687363
http://cds.cern.ch/record/687363
Autor:
Bouclier, Roger, Capeans, M, Hoch, M, Million, G, Ropelewski, L, Sauli, F, Sharma, A, Shekhtman, L
The present study aims to create reproducible and controlled polluted conditions in a clean gas system in order to be able to compare the behaviour of an MSGC plate operating with Ar-DME and Ne-DME gas mixtures. The achievement of such conditions see
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::30c6eb9e107126f59469b7265857f5ee
http://cds.cern.ch/record/687374
http://cds.cern.ch/record/687374
Autor:
Alunni, L, Bouclier, Roger, Fara, G, Garabatos, C, Manzin, G, Million, Gilbert, Ropelewski, Leszek, Sauli, Fabio, Shekhtman, L I, Daubie, Evelyne, Pingot, O, Pestov, Yu N, Busso, L, Costa, S
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::d2d2f52d36dc2d6863e5760156fac9ab
http://cds.cern.ch/record/254631
http://cds.cern.ch/record/254631
Autor:
Bouclier, Roger, Garabatos, C, Gaudaen, J, Florent, J J, Ropelewski, Leszek, Sauli, Fabio, Bondar, A E, Groshev, V R, Minakov, G D, Onuchin, A P, Pestov, Yu N, Shekhtman, L I, Sidorov, V A, Dixit, M S, Oakham, G K, Møller, S, Sørensen, G, Uggerhøj, Erik, Brons, S, Brückner, W, Godbersen, M, Heidrich, M, Paul, S, Trombini, A, Werding, R, Armitage, J A, Karlen, D A, Stewart, G, Barasch, E F, McIntyre, P, Pang, Y, Trost, H J, Salomon, M, Breskin, Amos, Chechik, R, Pansky, A
Gas Micro-Strip Chambers (GMSC) are a promising high-rate, high resolution position detector suited for use in high luminosity hadron collider experiments, as general purpose tracker or to improve the performances of pre-shower counters, transition r
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od________65::0adeb4291009bf33224ce4cf53291222
http://cds.cern.ch/record/291233
http://cds.cern.ch/record/291233