Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Borislav G. Tomov"'
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Borislav G. Tomov, Nathalie Sarup Panduro, Charlotte Mehlin Sorensen, Matthias Bo Stuart
Publikováno v:
Jensen, J A, Schou, M, Ommen, M L, Steenberg, K, Thomsen, E V, Tomov, B G, Panduro, N S, Sorensen, C M & Stuart, M B 2022, Synthetic Aperture High Quality B-mode Imaging with a Row-Column Array Compared to Linear Array Imaging . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9957973
Row-column (RC) matrix probes can yield 3-Dvolumetric imaging using a number of receiving elements similarto traditional linear arrays for commercial scanners. Some doubtshave, however, been raised on the B-mode image quality ofRC probes. It is hypot
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Lasse Thurmann Jorgensen, Borislav G. Tomov, Matthias Bo Stuart, Marie Sand Traberg, Iman Taghavi, Sigrid Huesebo Oygaard, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Nathalie Sarup Panduro, Michael Bachmann Nielsen, Charlotte Mehlin Sorensen
Publikováno v:
Jensen, J A, Schou, M, Jorgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Oygaard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sorensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article sum
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d1a139a50010404bebd1817b624c7df8
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Sofie Bech Andersen, Borislav G. Tomov, Stinne Byrholdt Sogaard, Charlotte Mehlin Sorensen, Michael Bachmann Nielsen, Carsten Gundlach, Hans Martin Kjer, Anders Bjorholm Dahl, Matthias Bo Stuart
Publikováno v:
Jensen, J A, Schou, M, Andersen, S B, Tomov, B G, Søgaard, S B, Sorensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B & Stuart, M B 2022, In Vivo Super Resolution Ultrasound Imaging using the Erythrocytes-SURE . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9958236
Current super resolution imaging is conducted using ultrasound contrast agents, where a sparse distribution ofbubbles must be employed to separate individual targets. Thesparse targets make the acquisition time long in the range of1 to 10 minutes, an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::75b17aacbeb3fe008314423b5c842e0c
https://orbit.dtu.dk/en/publications/2e8e67a1-b3b4-471b-90dc-d4c0808d8ab2
https://orbit.dtu.dk/en/publications/2e8e67a1-b3b4-471b-90dc-d4c0808d8ab2
Autor:
Rune Sixten Grass, Mathias Engholm, Andreas Spandet Havreland, Christopher Beers, Martin Lind Ommen, Stine Lovholt Grue Pedersen, Lars Nordahl Moesner, Matthias Bo Stuart, Mudabbir Tufail Bhatti, Borislav G. Tomov, Jorgen Arendt Jensen, Erik Vilain Thomsen
Publikováno v:
Grass, R S, Engholm, M, Havreland, A S, Beers, C, Ommen, M L, Pedersen, S L G, Moesner, L N, Stuart, M B, Bhatti, M T, Tomov, B G, Jensen, J A & Thomsen, E V 2022, ' A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging ', IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, vol. 2, 9913981, pp. 220-236 . https://doi.org/10.1109/OJUFFC.2022.3213013
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz cent
Autor:
Iman Taghavi, Mikkel Schou, Nathalie Sarup Panduro, Sofie Bech Andersen, Borislav G. Tomov, Charlotte Mehlin Sorensen, Matthias Bo Stuart, Jorgen Arendt Jensen
Publikováno v:
2022 IEEE International Ultrasonics Symposium (IUS)
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::303102cc2908eb80f6f7c8764f1683dd
Autor:
Jørgen A. Jensen, Mikkel Schou, Sofie B. Andersen, Stinne B. Søgaard, Charlotte M. Sørensen, Michael B. Nielsen, Carsten Gundlach, Hans Martin Kjer, Anders B. Dahl, Matthias B. Stuart, Borislav G. Tomov
Publikováno v:
Medical Imaging 2022: Ultrasonic Imaging and Tomography
Jensen, J A, Schou, M, Andersen, S B, Sogaard, S B, Sorensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B, Stuart, M B & Tomov, B G 2022, Fast Super Resolution Ultrasound Imaging using the Erythrocytes . in N Bottenus & N V Ruiter (eds), Medical Imaging 2022 : Ultrasonic Imaging and Tomography ., 120380E, SPIE, Progress in Biomedical Optics and Imaging-Proceedings of SPIE, vol. 12038, pp. 1-7, Medical Imaging 2022: Ultrasonic Imaging and Tomography, Virtual, Online, 21/03/2022 . https://doi.org/10.1117/12.2612245
Jensen, J A, Schou, M, Bech Andersen, S, Søgaard, S B, Sørensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B, Stuart, M B & Tomov, B G 2022, Fast super resolution ultrasound imaging using the erythrocytes . in Medical Imaging 2022: Ultrasonic Imaging and Tomography ., 120380E, SPIE-International Society for Optical Engineering, Proceedings of SPIE-The International Society for Optical Engineering, SPIE Medical Imaging 2022, San Diego, California, United States, 21/02/2022 . https://doi.org/10.1117/12.2612245
Proc. SPIE 12038, Medical Imaging 2022
Jensen, J A, Schou, M, Andersen, S B, Sogaard, S B, Sorensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B, Stuart, M B & Tomov, B G 2022, Fast Super Resolution Ultrasound Imaging using the Erythrocytes . in N Bottenus & N V Ruiter (eds), Medical Imaging 2022 : Ultrasonic Imaging and Tomography ., 120380E, SPIE, Progress in Biomedical Optics and Imaging-Proceedings of SPIE, vol. 12038, pp. 1-7, Medical Imaging 2022: Ultrasonic Imaging and Tomography, Virtual, Online, 21/03/2022 . https://doi.org/10.1117/12.2612245
Jensen, J A, Schou, M, Bech Andersen, S, Søgaard, S B, Sørensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B, Stuart, M B & Tomov, B G 2022, Fast super resolution ultrasound imaging using the erythrocytes . in Medical Imaging 2022: Ultrasonic Imaging and Tomography ., 120380E, SPIE-International Society for Optical Engineering, Proceedings of SPIE-The International Society for Optical Engineering, SPIE Medical Imaging 2022, San Diego, California, United States, 21/02/2022 . https://doi.org/10.1117/12.2612245
Proc. SPIE 12038, Medical Imaging 2022
Super resolution (SR) imaging is currently conducted using fragile ultrasound contrast agents. This precludes using the full acoustic pressure range, and the distribution of bubbles has to be sparse for them to be isolated for SR imaging. Images have
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::bac2cdc29933dfff3514043b80003cbd