Zobrazeno 1 - 10
of 61
pro vyhledávání: '"Bmc McCurdy"'
Publikováno v:
Physics in Medicine and Biology. 62:1600-1612
This study reports the development and validation of a model-based, 3D patient dose reconstruction method for pre-treatment quality assurance using EPID images. The method is also investigated for sensitivity to potential MLC delivery errors. Each ci
Autor:
D. Sasaki, Bashir Bashir, Julian O. Kim, S. Kumaragamage, Rashmi Koul, E. VanUytven, Andrew Cooke, Maged Nashed, Bmc McCurdy, R. Kulshrestha
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 108:e271
Publikováno v:
Medical physics. 39(7Part3)
As radiation treatment delivery becomes more complex, including dynamic IMRT and VMAT, the argument for routine patient dose verification becomes more compelling. This work demonstrates a technique that utilizes our pre-existing portal dose image pre
Publikováno v:
Medical physics. 39(7Part2)
Purpose: PARETO (Pareto‐Aware Radiotherapy Evolutionary Treatment Optimization) is a novel multiobjective treatment planning system that performs beam orientation and fluence optimization simultaneously using an advanced evolutionary algorithm. In
Autor:
K Chytyk, Bmc McCurdy
Publikováno v:
Medical physics. 35(7Part2)
Amorphous silicon (a‐Si) electronic portal imaging devices(EPIDs) have been heavily investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy(IMRT). This verification could be accomplished throug
Autor:
P Potrebko, Bmc McCurdy
Publikováno v:
Medical physics. 35(7Part3)
A beam orientation optimization (BOO) algorithm based on optimizing beam intersection volume (BIV) components within an Organ-at-Risk (OAR) is proposed to improve conventional intensity-modulated radiation therapy (IMRT). A simulated annealing algori
Publikováno v:
Radiotherapy and Oncology. 127:S350-S351
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 102:e497
Autor:
Philip McGeachy, M. Riel, Bmc McCurdy, D. Sasaki, J. Beaudry, Chad Harris, Arbind Dubey, M. Smyth, D Rickey, Ankur Sharma, Rashmi Koul, J. Brown, S.L. Iftody
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 99:E413-E414
Autor:
K Chytyk, Bmc McCurdy
Publikováno v:
Medical Physics. 36:1389-1398
Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) continue to be investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy (IMRT). This verification could be accomplished through a