Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Bloom, J.G.P."'
Publikováno v:
Materials Evaluation, 5, 69, 547-552
The feasibility of the inspection of flow line hubs using the phased array technique was investigated to determine the surface area of the seal area degraded by corrosion. A clean model of the hub was simulated to gain insight into the geometrical ec
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::d448fe358272ef64ffc599fa321a04f6
http://resolver.tudelft.nl/uuid:a1ef600a-be4f-4b98-a288-f18cf5a5ee8d
http://resolver.tudelft.nl/uuid:a1ef600a-be4f-4b98-a288-f18cf5a5ee8d
This report presents the results of the AERTOs project, an ERA-NET project of seven RTOs in Europe: Fraunhofer, CEA, SINTEF, SP, TNO, Tecnalia and VTT. The objective is to identify, design and implement “joint, long-term, sustainable cooperation ac
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::eb3ad7390eff7f3b5a43618be4f594e8
http://resolver.tudelft.nl/uuid:e00d3627-447d-4c45-8a56-540b61b9d167
http://resolver.tudelft.nl/uuid:e00d3627-447d-4c45-8a56-540b61b9d167
Publikováno v:
37th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE 2010, 18-23 July 2010, San Diego, CA, USA, 1335, 647-654
Inspection of corrosion at pipe support locations is difficult because of accessibility limitations. Recently a screening technique has been developed called Multi-Skip ultrasonics. The method utilizes a pitch-catch set-up. Shear waves are transmitte
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::c9bcd4f79c0db1b73e549abe87dc9efe
http://resolver.tudelft.nl/uuid:4b24f0da-12de-427c-92f0-7a809dabb705
http://resolver.tudelft.nl/uuid:4b24f0da-12de-427c-92f0-7a809dabb705
Autor:
Volker, A.W.F., Bloom, J.G.P.
Publikováno v:
37th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE 2010, 18-23 July 2010, San Diego, CA, USA, 1335, 223-230
The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections. Guided wave tomography has been developed to map the wall thickness
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::ded54ad203cb364ff5ce05b82477f53f
http://resolver.tudelft.nl/uuid:f1000ad2-449e-4724-b0d0-98e9c3d7d103
http://resolver.tudelft.nl/uuid:f1000ad2-449e-4724-b0d0-98e9c3d7d103
Autor:
Volker, A.W.F., Bloom, J.G.P.
Publikováno v:
37th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE 2010, 18-23 July 2010, San Diego, CA, USA, 1335, 215-222
Corrosion is one of the industries major issues regarding the integrity of assets. Currently inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Cost reduction while maintaining a high level of relia
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::d29c72176349f36ead6cbd21e6a6474e
http://resolver.tudelft.nl/uuid:39b6c1d6-b357-49be-9e93-e19877da34ca
http://resolver.tudelft.nl/uuid:39b6c1d6-b357-49be-9e93-e19877da34ca
Publikováno v:
36th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE 2009, 26-31 July 2009, Kingston, RI, USA, 1211, 1911-1918
Risk based inspection strategies rely on detailed knowledge of the performance of inspection techniques. The objective of the "POD generator" project is to develop a numerical modeling approach to assess the effectiveness of specific inspection techn
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::bed7a3f002a9b38c5f51fee15b8cc4e2
http://resolver.tudelft.nl/uuid:8be4ed6d-f87d-4b49-a039-7ee63418383d
http://resolver.tudelft.nl/uuid:8be4ed6d-f87d-4b49-a039-7ee63418383d
Publikováno v:
Review of Progress in Quantitative Nondestructive Evaluation, 20-25 July, 2008, Chicago, IL, USA, 1096, 727-734
Guided wave tomography is a promising technique for the monitoring of corrosion over large areas. Guided waves have a wave speed mat depends in certain frequency-thickness regimes on the local thickness of the waveguide they follow. Therefore, the tr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::56fa1fb4cd232ced8503c727ca633cc5
http://resolver.tudelft.nl/uuid:f6826111-ebac-414b-845d-6a9976d944bb
http://resolver.tudelft.nl/uuid:f6826111-ebac-414b-845d-6a9976d944bb
Publikováno v:
2009 ASME Pressure Vessels and Piping Conference, PVP 2009, 26-30 July 2009, Prague, Czechoslovakia, 225-230
Corrosion and erosion are two major degradation mechanisms of piping systems and pipelines that both lead to wall thickness loss. To ensure sufficient integrity levels of these assets NDE is currently conducted at time based intervals often associate
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::dad9f502b6955f7ba34371957cda3bce
http://resolver.tudelft.nl/uuid:65247d32-91bc-4d1e-acda-286991b00f8d
http://resolver.tudelft.nl/uuid:65247d32-91bc-4d1e-acda-286991b00f8d
Autor:
Bloom, J.G.P., Stelwagen, U., Mast, A., Volker, A.W.F., Krom, A.H.M., Mohamoud, A.A., Gils, G.P. van
Publikováno v:
Review of Progress in Quantitative Nondestructive Evaluation, 20-25 July 2008, Chicago, IL, USA, 1096, 1816-1823
Risk based inspection strategies rely on detailed knowledge of the performance of inspection techniques. It is well known that every inspection technique has limitations in terms of reliability and effectiveness. Moreover, these are influenced by man
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::b062e9896b5b557f7ef3141e597a9bd0
http://resolver.tudelft.nl/uuid:fa225539-e6e6-49ea-9746-02ffea80f80a
http://resolver.tudelft.nl/uuid:fa225539-e6e6-49ea-9746-02ffea80f80a
Publikováno v:
36th Annual Review of Progress in Quantitative Nondestructive Evaluation, QNDE 2009, 26-31 July 2009, Kingston, RI, USA, 1211, 774-781
The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections. The method should be capable of providing quantitative wall thicknes
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::df5ea48db775aa3aa1035138ccd94714
http://resolver.tudelft.nl/uuid:94dc354e-9855-4334-9715-cdb1e2244325