Zobrazeno 1 - 10
of 301
pro vyhledávání: '"Bevatron"'
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 479:23-34
The dynamics of relativistic uranium-ion beams stripped by foils from Be to Au is investigated in the 100–500 MeV/u energy range. Calculations of the charge-state distributions of uranium fractions as a function of foil thickness are performed usin
Publikováno v:
Physical Review A. 101
The dynamics of charge-state fractions of relativistic gold-ion beams stripped by foils from Be to Au is investigated in the 100 MeV/u to 10 GeV/u energy range. Calculations of the fractions as a function of foil thickness are performed using the rec
Autor:
J. M. Schippers
Publikováno v:
IEEE Transactions on Nuclear Science. 63:939-948
After the invention of the cyclotron by Ernest Lawrence and Robert Wilson’s suggestion to use the Bragg peak in the depth-dose distribution of protons to apply a high radiation dose selectively into a tumor, the first patient was treated with energ
Autor:
J. Steinberger
Publikováno v:
From the PS to the LHC-50 Years of Nobel Memories in High-Energy Physics ISBN: 9783642308437
The CERN PS, which started in 1959, and the Brookhaven AGS in 1960, represented an advance by a factor of more than five in the energy of proton accelerators, from the 5 GeV of the Berkeley Bevatron to about 30 GeV. These accelerators made possible t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d7ea7ea740fffb114670e6670af95eb5
https://doi.org/10.1007/978-3-642-30844-4_1
https://doi.org/10.1007/978-3-642-30844-4_1
Autor:
Subal Das Gupta, Gary Westfall
Publikováno v:
Physics Today. 46:34-40
A 150‐meter‐long outdoor beam line wanders through eucalyptus trees down the 45‐meter slope connecting the SuperHILAC and the Bevatron at the Lawrence Berkeley Laboratory. The SuperHILAC is a linear accelerator designed to accelerate heavy nucl
Publikováno v:
Thomas, Ralph H.; Smith, Alan R.; & Zeman, Gary H.(2008). A reappraisal of the reported dose equivalents at the boundary of the University of California Radiation Laboratory during the early days of Bevatron operation. Lawrence Berkeley National Laboratory. Lawrence Berkeley National Laboratory: Lawrence Berkeley National Laboratory. Retrieved from: http://www.escholarship.org/uc/item/2hr0p0rf
Accelerator-produced radiation levels at the perimeter of the Ernest Orlando Lawrence Berkeley National Laboratory (the Berkeley Laboratory) reached a maximum in 1959. Neutrons produced by the Bevatron were the dominant component of the radiation fie
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od_______325::c1b5f65302db5c5d1b7ac98e24c684ac
http://www.escholarship.org/uc/item/2hr0p0rf
http://www.escholarship.org/uc/item/2hr0p0rf
Autor:
C. Westfall
Using radioactive materials obtained by chance, a turntable employing gears from Heidelberg's mechanical toy shops, and other minimal equipment available in post World War II Germany, in 1959 Rudolf Moessbauer confirmed his suspicion that his graduat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::dd59dfe969306070126fff0173f077db
https://doi.org/10.2172/881585
https://doi.org/10.2172/881585
Publikováno v:
Proceedings of the 1989 IEEE Particle Accelerator Conference, . 'Accelerator Science and Technology.
The Bevatron/Bevalac main guide field power supply stores 680 MJ in the flywheel-shaft systems of two independent motor-generator sets. During the normal acceleration cycle of various heavy-ion beams, the energies of the rotating shafts are converted
Publikováno v:
Proceedings of the 1989 IEEE Particle Accelerator Conference, . 'Accelerator Science and Technology.
The Bevatron/Bevalac main guide field power supply was originally designed to provide a 15250-V DC at 8400-A peak magnet pulse. Protons were accelerated to 6.2 GeV. The 128-MW pulse required two large motor-generator (MG) sets with 67-ton flywheels t
Autor:
G.D. Stover, Emery Zajec
Publikováno v:
Proceedings of the 1989 IEEE Particle Accelerator Conference, . 'Accelerator Science and Technology.
Performance tests of the Bevatron local injector duoplasmatron ion source using singly charged particles of helium and deuterium are described. Initial measurements of the 8.4-keV/nucleon helium 1+ beam and deuterium 1+ beams indicated intensities of