[EN] Steel reinforcing bars are often coated with rusts formed during service in reinforced concrete (RC) structures. Rust layers growing on steel rebars induce expansive stresses and cause cracking on cover concrete. This study uses steel corrosion
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::c7a07d9847f34a745da2f3bc19c06b96
http://hdl.handle.net/10261/187179
http://hdl.handle.net/10261/187179
Autor:
Bastidas, David M., Ress, J., Bosch, J., La Iglesia, A., Bastidas Rull, José María, Martin, Ulises
Publikováno v:
Revista de Metalurgia; Vol. 56 No. 1 (2020); e164
Revista de Metalurgia; Vol. 56 Núm. 1 (2020); e164
Revista de Metalurgia
Consejo Superior de Investigaciones Científicas (CSIC)
Revista de Metalurgia, Vol 56, Iss 1, Pp e164-e164 (2020)
Digital.CSIC. Repositorio Institucional del CSIC
instname
Revista de Metalurgia; Vol. 56 Núm. 1 (2020); e164
Revista de Metalurgia
Consejo Superior de Investigaciones Científicas (CSIC)
Revista de Metalurgia, Vol 56, Iss 1, Pp e164-e164 (2020)
Digital.CSIC. Repositorio Institucional del CSIC
instname
The rust layer formed on carbon steel exposed to natural marine and urban-continental envi-ronments for up to 50 years was studied. Mineralogical phase composition of the rust layer was evaluated by X-ray diffraction (XRD), akaganeite, goethite, lepi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::0162865f9aeb3127a1fad68f4db03009
https://revistademetalurgia.revistas.csic.es/index.php/revistademetalurgia/article/view/1480
https://revistademetalurgia.revistas.csic.es/index.php/revistademetalurgia/article/view/1480
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
Corrosion of reinforced concrete structures is nowadays one of the major concerns on the durability and serviceability of buildings and constructions. Corrosion management and monitoring of infrastructure and civil engineering structures are required
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::9daf4e08b2d35a1b5cd1b984ccd942e1
http://hdl.handle.net/10261/221248
http://hdl.handle.net/10261/221248
Autor:
Castorena-González, J.H., Gaona-Tiburcio, Citlali, Bastidas, David M., Núñez-Jáquez, R.E., Bastidas Rull, José María, Almeraya-Calderón, Facundo
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
A finite element (FE) method was proposed to calculate the corrosion penetration depth (r) on steel reinforcement necessary for the first visible crack to appear on the concrete cover. The FE analysis was carried out using the commercial software fro
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::6c93f84a9f32ca65af99adf630ae5b32
http://hdl.handle.net/10261/206972
http://hdl.handle.net/10261/206972
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
Military assets require the implementation of corrosion control and monitoring techniques, in particular during long periods of storage. Plastic sheets and/or textile canvas, impregnated with vapor phase inhibitors, are used to cover weapons and vehi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::9195b6ce33854e78abbc215151026486
http://hdl.handle.net/10261/136832
http://hdl.handle.net/10261/136832
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. A new test electrochemical cell is described for monitoring the steel microbiologically induced corrosion and numerical simulations were performed using finite element method to demonstrate the suit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::158cd46b4d5d6820cf2fcefdd1a09807
http://hdl.handle.net/10261/129057
http://hdl.handle.net/10261/129057
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
This paper shows how the last algebraic matricial form can be obtained when the finite element method is used to approximate the potential distribution of a cathodic protection system that includes low conductivity irregularities in the electrolyte a
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
Electrochemical impedance spectroscopy (EIS) and polarisation curves assisted by Raman spectroscopy were used to study the corrosion behaviour and to characterise the corrosion products of reinforcing steel embedded in fly ash mortars with and withou
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::0f1280fa4debc72617b5347a27db67d0
http://hdl.handle.net/10261/87502
http://hdl.handle.net/10261/87502
Autor:
Cano Díaz, Emilio, Bastidas Rull, José María, Lafuente, Diana, Bastidas, David M., Criado, María, Fajardo, S.
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
4 páginas, 2 figuras. Ed. Miguel Ángel Rogerio Candelera y Cesáreo Sáiz Jiménez. Primera Reunión de la Red de Ciencia y Tecnología para la Conservación del Patrimonio (Madrid, 28-29 de junio de 2011).
La corrosión, es decir, la reacció
La corrosión, es decir, la reacció
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::8813a2827976cc90a8e19b95d29f5ad0
http://hdl.handle.net/10261/47282
http://hdl.handle.net/10261/47282
Publikováno v:
Digital.CSIC. Repositorio Institucional del CSIC
instname
instname
Trabajo invitado de la Revista de Metalurgia.
Ant-nest corrosion is a specific type of premature failure (2-3 months) of copper tubes used in air-conditioning units causing the loss of refrigerant liquid and the consequent environment pollution.