Zobrazeno 1 - 10
of 63
pro vyhledávání: '"Banchong Mahaisavariya"'
Autor:
Chantas Mahaisavariya, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Nattapon Chantarapanich
Publikováno v:
Journal of Orthopaedic Surgery and Research, Vol 19, Iss 1, Pp 1-9 (2024)
Abstract Background Basicervical femoral neck fracture is a rare proximal femur fracture with a high implant failure rate. Biomechanical comparisons between cephalomedullary nails (CMNs) and dynamic hip screws (DHSs) under torsion loading are lacking
Externí odkaz:
https://doaj.org/article/4eeb32d7e73d4a5da691a6afc7026929
Autor:
Chantas Mahaisavariya, Nomina Pradhan, Kongkhet Riansuwan, Theerawoot Tharmviboonsri, Likit Rugpolmuang, Banchong Mahaisavariya, Direk Tantigate
Publikováno v:
Siriraj Medical Journal, Vol 74, Iss 10 (2022)
Objective: A cephalomedullary nail is the treatment of choice for trochanteric fractures; however, a lag screw cutout is one of the most devastating complications. The lag screw cut-out rate was reported to be around 2.5%–8.3%. This study aimed to
Externí odkaz:
https://doaj.org/article/12b253a1fc15456d80aa80aa8df4c1c1
Publikováno v:
Siriraj Medical Journal, Vol 63, Iss 3 (2020)
A surgical technique to drain the medullary content during closed femoral nailing by using a Frazier suction tip as a vent is demonstrated. This method is simple, safe and reproducible. The medullary content can be drained outside without surrounding
Externí odkaz:
https://doaj.org/article/161a8d5fdbdf4462a48fd36e1928c88c
Publikováno v:
Case Reports in Orthopedics, Vol 2013 (2013)
This report presents a surgical technique to remove a broken cannulated nail from the femur. A Harrington rod was modified for retrograde impaction of the retained fragment. The broken implant was finally removed without complication. This particular
Externí odkaz:
https://doaj.org/article/27a2ad36072046a38d88b6ebf1c946d8
Autor:
Banchong Mahaisavariya
Publikováno v:
Siriraj Medical Journal, Vol 58, Iss 12 (2006)
Externí odkaz:
https://doaj.org/article/2950febeb2bc45fcbdbd3e531819c96c
Autor:
Banchong Mahaisavariya
Publikováno v:
Siriraj Medical Journal, Vol 57, Iss 6 (2005)
Externí odkaz:
https://doaj.org/article/6a0c4080a63547b99f99be67d434a838
Autor:
Nattapon Chantarapanich, Surasak Jitprapaikulsarn, Banchong Mahaisavariya, Chantas Mahaisavariya
Publikováno v:
Medical Engineering & Physics. 107:103856
A smaller dimension of the femoral neck in the Asian population may have difficulty placing inverted triangle multiple screws configuration for treatment. Posterior triangle configuration, which is suitable in limited space of the femoral neck, is a
Autor:
Prasert Chalermkarnnon, Sattaya Rojanasthien, Kavin Karunratanakul, Kriskrai Sitthiseripratip, Bancha Chernchujit, Nattapon Chantarapanich, Banchong Mahaisavariya, Chinnawit Glunrawd
Publikováno v:
Journal of Orthopaedic Science. 22:703-709
Purpose To assess morphological parameters of proximal femur and acetabulum in Thai population with three-dimensional measurement technique, and to analysis of collateral side symmetric, gender difference, and correlation between morphometric paramet
Autor:
Kriskrai Sitthiseripratip, Pongwit Siribodhi, Nattapon Chantarapanich, Banchong Mahaisavariya
Publikováno v:
Medical & Biological Engineering & Computing. 54:939-952
The study compared the biomechanical performance of retrograde nail used to stabilize supracondylar fracture (three different levels) by means of finite element analysis. Three different nail lengths (200, 260, and 300 mm) of stainless steel and tita
Publikováno v:
Clinics in Orthopedic Surgery
A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a surgical technique and the modified instrument that was available in the o