Zobrazeno 1 - 10
of 44
pro vyhledávání: '"Balles, Andreas"'
Autor:
Balles, Andreas
As a non-destructive testing method, X-ray imaging has proved to be suitable for the examination of a variety of objects. The measurement principle is based on the attenuation of X-rays caused by these objects. This attenuation can be recorded as sha
Autor:
Kavka, Mareike1 (AUTHOR) kavka@ipk-gatersleben.de, Balles, Andreas2 (AUTHOR), Böhm, Christof3 (AUTHOR), Dehmer, Klaus J.1 (AUTHOR), Fella, Christian2 (AUTHOR), Rose, Felix4 (AUTHOR), Saal, Bernhard5 (AUTHOR), Schulze, Sabine6 (AUTHOR), Willner, Evelin1 (AUTHOR), Melzer, Michael4 (AUTHOR)
Publikováno v:
BMC Plant Biology. 6/19/2024, Vol. 24 Issue 1, p1-14. 14p.
Autor:
Müller, Dominik, Graetz, Jonas, Balles, Andreas, Stier, Simon, Hanke, Randolf, Fella, Christian
In a comprehensive study on several samples we demonstrate for our laboratory-based computed tomography system resolutions down to 150nm. The achieved resolution is validated by imaging com-mon test structures in 2D and Fourier Shell Correlation of 3
Externí odkaz:
http://arxiv.org/abs/2102.06644
Publikováno v:
JINST 16 (2021) P01034
The ntCT nano tomography system is a geometrically magnifying X-ray microscopy system integrating the recent Excillum NanoTube nano-focus X-ray source and a CdTe photon counting detector from Dectris. The system's modulation transfer function (MTF) a
Externí odkaz:
http://arxiv.org/abs/2009.11749
Publikováno v:
Phys. Med. Biol. 65 (2020) 235017
Talbot(-Lau) interferometric X-ray darkfield imaging has, over the past decade, gained substantial interest for its ability to provide insights into a sample's microstructure below the imaging resolution by means of ultra small angle scattering effec
Externí odkaz:
http://arxiv.org/abs/2007.08042
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
J. Imaging 2018, 4(6), 77
The diffraction contrast modalities accessible by X-ray grating interferometers are not imaged directly but have to be inferred from sine like signal variations occurring in a series of images acquired at varying relative positions of the interferome
Externí odkaz:
http://arxiv.org/abs/1804.10978
Autor:
Mueller, Dominik, Fella, Christian, Altmann, Frank, Graetz, Jonas, Balles, Andreas, Ring, Matt, Gambino, Jeff
Publikováno v:
In Microelectronics Reliability August 2022 135
Autor:
Blum, Kai, Wiest, Wolfram, Fella, Christian, Balles, Andreas, Dittmann, Jonas, Rack, Alexander, Maier, Dominik, Thomann, Ralf, Spies, Benedikt Christopher, Kohal, Ralf Joachim, Zabler, Simon, Nelson, Katja
Publikováno v:
In Dental Materials November 2015 31(11):1415-1426
Autor:
Müller, Dominik, Graetz, Jonas, Balles, Andreas, Stier, Simon, Hanke, Randolf, Fella, Christian
Publikováno v:
Crystals, Vol 11, Iss 677, p 677 (2021)
Crystals
Volume 11
Issue 6
Crystals
Volume 11
Issue 6
In a comprehensive study, we demonstrate the performance and typical application scenarios for laboratory-based nano-computed tomography in materials research on various samples. Specifically, we focus on a projection magnification system with a nano