Autor:
Bahadır Akbal
Publikováno v:
Pamukkale University Journal of Engineering Sciences, Vol 23, Iss 2, Pp 119-125 (2017)
Kılıf akımı yüksek gerilim yeraltı kablolu hatlarda arızalara ve elektrik çarpılmalarına neden olmaktadır. Ayrıca kabloda ek ısı meydana getirerek kablonun akım taşıma kapasitesini düşürür. Kılıf akımını düşürmek için fa
Externí odkaz:
https://doaj.org/article/d1e73b9648154d3a85eac1916840cda2
Autor:
Bahadır Akbal
Publikováno v:
IET Generation, Transmission & Distribution. 14:4331-4338
Cable termination fault (CTF) generally occurs due to increasing of electrical force (EF) and thermal effect (TE) in mixed line. EF increases due to sheath voltage (SV), and TE increases due to harmonic distortion (HD) on cable terminations (CTs). Al
Autor:
Bahadır Akbal
Publikováno v:
International Transactions on Electrical Energy Systems. 30
Autor:
Bahadır Akbal
Publikováno v:
International Journal of Engineering and Technology. 9:40-44
Autor:
Bahadır Akbal
Publikováno v:
Pamukkale University Journal of Engineering Sciences. 23:119-125
WOS: 000443167700004
The sheath current causes cable faults and electroshock risk in high voltage underground cable lines. Also the sheath current increases cable temperature and it reduces cable ampacity. Hence, cable performance decreases due
The sheath current causes cable faults and electroshock risk in high voltage underground cable lines. Also the sheath current increases cable temperature and it reduces cable ampacity. Hence, cable performance decreases due
Autor:
Bahadır Akbal
Publikováno v:
Electric Power Systems Research. 187:106513
Cable termination fault (CTF) is a major problem for high voltage cable lines (HVCL). Increasing of the sheath voltage (SV), zero sequence current (ZC) and current harmonic distortion (THDI) on metallic sheath (MS) of HVC are major factors for CTF. M
Autor:
Bahadir Akbal
Publikováno v:
Elektronika ir Elektrotechnika, Vol 25, Iss 6, Pp 8-14 (2019)
Cable termination fault is one of the most important problems for high voltage underground cable lines (HVUCL). Harmonic current (HC) and the sheath current (SC) are causes of cable termination faults of HVUCL. The sheath voltage (SV) of cable increa
Externí odkaz:
https://doaj.org/article/c268b57200734ce188a5a537e871f4e1
Autor:
Bahadir Akbal
Publikováno v:
Elektronika ir Elektrotechnika, Vol 24, Iss 2, Pp 31-36 (2018)
High temperature causes aging of insulation material of high voltage underground cable line (HVUL), so cable faults occurs. The sheath current (SC) is the most important factor for increasing of cable temperature, and SC can include harmonic, so cabl
Externí odkaz:
https://doaj.org/article/1cf9b04f42e24811bc886e2a48b5eeb5