Zobrazeno 1 - 10
of 12
pro vyhledávání: '"B.R. Shankara Reddy"'
Publikováno v:
Journal of Electrocardiology. 30:28-33
A new microprocessor-assisted cardiac rhythm algorithm (MAC-RHYTHM), based on median QRST subtraction from 10-second electrocardiographic (ECG) data, was prospectively tested on 10,761 ECGs acquired at one of three clinical centers. Atrial waves (P w
Publikováno v:
Journal of Electrocardiology. 29:62-66
As part of the International Electrotechnical Commission's (IEC) efforts to develop standards for interpretive electrocardiographs, electrocardiograms (ECGs) of the Common Standards of Electrocardiography (CSE) multilead measurement database were pro
Autor:
Stephen C. Hammill, Yukio Ozawa, Hugo Ector, C Timmermans, Michael G. Kienzle, B.R. Shankara Reddy, Donald A. Underwood, Kenneth W. Haisty
Publikováno v:
Pacing and Clinical Electrophysiology. 17:303-311
There is only limited data on normal reference values for signal-averaged electrocardiograms (SAECGs) using Frank leads and fast Fourier transform filter (FFT). Furthermore, the influence of gender on reference values and their relation to body chara
Publikováno v:
Journal of Electrocardiology. 22:33-40
The high-resolution electrocardiography has become an important clinical tool for analyzing the high-frequency content of electrocardiograms (ECGs). Recent emphasis has been on the detection of ventricular late potential activity due to its ability t
Autor:
B.R. Shankara Reddy, Qiuzhen Xue
Publikováno v:
Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
Three time-frequency (T-F) methods are evaluated for recognition of late potentials. These methods are: short-time Fourier transform (STFT), autoregressive modeling, and Wigner transform. For each method, the procedures include T-F processing, featur
Publikováno v:
Journal of electrocardiology.
Analysis of high frequency (150–250 Hz) in the signal-averaged electrocardiogram (SAECG) is one of the emerging methods for detecting vessel patency in acute myocardial infarction following thrombolytic therapy and angioplasty. Root-mean-square vol
Publikováno v:
Journal of electrocardiology.
High-resolution (HI-RES) ECG analysis software and a new front end have been designed for a standard 12-lead ECG cart, MAC-12. The front end acquires orthogonal ECG at 1,000 samples/sec and 1.2 μ V/bit and transmits to the cart. The HI-RES software
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.