Zobrazeno 1 - 10
of 23
pro vyhledávání: '"B. W. Sauer"'
Publikováno v:
Journal of Biomedical Materials Research. 9:537-542
The results of the present study demonstrate the utility of the scanning electron microscope for characterizing the ultrastructure of the initial tissue infiltrate in porous polyethylene implants. Shortly after implantation a thin noncellular fibrous
Publikováno v:
Journal of Biomedical Materials Research. 10:595-603
The purpose of this study was to delineate the process by which bone comes to fill the pores of porous high-density polyethylene (PHDPE) implants. PHDPE (450μ pore size) pellets 4 mm in diameter and 1 cm long were implanted into the femurs of dogs.
Publikováno v:
Journal of Biomedical Materials Research. 7:85-95
The mastoid process of the temporal bone can become infected with possible serious complications. If the infection does not respond to antibiotics, the infected area must be surgically removed, with the result that a cavity is formed. This cavity mus
Publikováno v:
Journal of biomedical materials research. 9(4)
Disk-shaped implants of spinel, alumina, mullite, zircon, a cast Co-Cr-Mo alloy, and ultra-high molecular weight polyethylene (UHMWPE), were implanted in the paraspinalis muscle of 12 adult, male, white New Zealand rabbits. Prior to implantation the
Publikováno v:
Surfaces and Interfaces of Glass and Ceramics ISBN: 9781468431469
Porous titania and porous porcelain were selected for this investigation* because of their chemical inertness and ease of fabrication. Titanium metal implants have demonstrated a high degree of tissue tolerance1,2; these are certain to have maintaine
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::addeca99371fb1ba42d3f6aa84c9f3b7
https://doi.org/10.1007/978-1-4684-3144-5_16
https://doi.org/10.1007/978-1-4684-3144-5_16
Publikováno v:
Clinical orthopaedics and related research. (121)
The properties of self-curing polymethylmethacrylate as affected by the admixing of an antibiotic to the powder-liquid mixture and as affected by insertion technique demonstrated that the antibiotic agent may leach from the surface of the acrylic, bu
Publikováno v:
Engineering in Medicine ISBN: 9783642663710
Polymeric materials have been widely used as soft tissue and non-weight bearing implants for a number of years. However, the successful use of polymeric materials in high load bearing joints is a much more recent development. The prosthetic replaceme
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::61dc684ec3c80ec32e3941cff6711ad8
https://doi.org/10.1007/978-3-642-66369-7_18
https://doi.org/10.1007/978-3-642-66369-7_18
Publikováno v:
Journal of rehabilitation research and development. 26(4)
Quadriplegics rely on mouth-controlled devices to perform a variety of tasks and to establish some degree of self-sufficiency. The most functional mouthstick appliances have custom-fitted mouthpieces which are fabricated by dental professionals, and
Autor:
B W, Sauer, R B, Lade
Publikováno v:
Transactions - American Society for Artificial Internal Organs. 28
This study has demonstrated the feasibility of using PHDPE/autogenous tissue tracheal prostheses to repair defects in the cervical trachea. The PHDPE rings have proven to be an efficacious method of providing a noncollapsing, yet flexible airway. The
Publikováno v:
Journal of biomedical materials research. 9(4)
This investigation attempts to apply the concept of direct skeletal attachment via tissue ingrowth to the attachment of femoral head prostheses to the femur. Stainless steel (316L) canine femoral head prostheses with a ceramic coated stem were implan