Zobrazeno 1 - 10
of 10
pro vyhledávání: '"B. P. Ajith Kumar"'
Publikováno v:
Pramana. 90
A $$\gamma $$ -ray spectroscopy system based on a 1 $$^{\prime \prime }\times 1^{\prime \prime }$$ NaI(Tl) detector and 1.5 $$^{\prime \prime }$$ photomultiplier tube has been developed at IUAC for teaching laboratory applications involving radioacti
Autor:
Rajesh Kumar, T. Varughese, J. Zacharias, Mukesh Kumar, E.V. Prasad, Akhil Jhingan, G. Mohanto, J. J. Das, Anup Choudhury, B. P. Ajith Kumar, P. Sugathan, S. Muralithar, P. Barua, U. G. Naik, Sunil Kalkal, J. Gehlot, K. Rani, R. K. Bhowmik, A. Roy, M. Archunan, K. S. Golda, A. K. Mandal, S. Nath, A. J. Malyadri, Reeshu Singh, Tripti Sekhar Datta, S.K. Suman, J. Chacko, R. P. Singh, S.V.L.S. Rao, N. Madhavan, A. K. Sinha, E. T. Subramanian, Rakesh Kumar, M. C. Radhakrishna, K. M. Varier
Publikováno v:
Pramana. 75:317-331
Hybrid recoil mass analyzer (HYRA) is a unique, dual-mode spectrometer designed to carry out nuclear reaction and structure studies in heavy and medium-mass nuclei using gas-filled and vacuum modes, respectively and has the potential to address newer
Autor:
Hardev Singh, Akhil Jhingan, Rohit Sandal, P. Sugathan, K. M. Varier, K. S. Golda, B. P. Ajith Kumar, B. R. Behera, J. J. Das, R. G. Thomas, S. Kailas, E.V. Prasad, N. Madhavan, B. R. S. Babu, A. K. Sinha, Reeshu Singh, J. Gehlot, Sukhendu Nath
Publikováno v:
Nuclear Physics A. 834:208c-211c
Fission fragment mass angle correlation and mass ratio distributions have been measured for 16 O + 194 Pt reaction forming the composite system 210 Rn in the energy range 75 MeV to 102 MeV in laboratory frame. No mass angle correlation was observed a
Autor:
J. Chacko, S. Ghosh, M. V. Suresh Babu, Rajesh Kumar, Arvind Chandra Pandey, S Venkatramanan, D.S. Mathuria, A. K. Rai, B. P. Ajith Kumar, A. K. Mandal, Manoj Kumar, Tripti Sekhar Datta, R.S. Meena, S. Kar, Joby Antony, J. Zacharias, B. K. Sahu, Anup Choudhury, S.S.K. Sonti, G K Chadhari, P.N. Prakash, R. K. Bhowmik, A. Roy, P. Barua, A. Sarkar, R. Mehta, K.K. Mistri, S.A. Krishnan
Publikováno v:
Pramana. 59:849-858
This paper reports the construction of a superconducting linear accelerator as a booster to the 15 UD Pelletron accelerator at Nuclear Science Centre, New Delhi. The LINAC will use superconducting niobium quarter wave resonators as the accelerating e
Autor:
K. Rani, Rajesh Kumar, A. J. Malyadri, Supriya Saini, Ruby Shanti, S. Muralithar, Rakesh Kumar, B. P. Ajith Kumar, R. K. Bhowmik
Publikováno v:
Pramana. 57:215-218
An indigenously developed automatic liquid nitrogen (LN2) filling system has been installed in gamma detector array (GDA) facility at Nuclear Science Centre. Electro-pneumatic valves are used for filling the liquid nitrogen into the high purity germa
Autor:
B. P. Ajith Kumar, N. Madhavan, A. K. Sinha, S. Kailas, B. Satheesh, E.V. Prasad, S. Nath, Akhil Jhingan, P. Sugathan, B. R. S. Babu, Jhilam Sadhukhan, K. S. Golda, Santanu Pal, K. M. Varier, J. Gehlot, G. Mohanto, T. Varughese, Reeshu Singh, Sunil Kalkal
Publikováno v:
EPJ Web of Conferences, Vol 17, p 16011 (2011)
Evaporation residue (ER) excitation function in the complete fusion of 16O with 194Pt is measured around the Coulomb barrier using gas-filled mode of the HYbrid Recoil mass Analyser (HYRA) at the Inter University Accelerator Centre (IUAC), New Delhi
Autor:
E.V. Prasad, S. Appannababu, S. Nath, P. Sugathan, Gayatri Mohanto, K. S. Golda, A. M. Vinodkumar, S. Kailas, M. M. Musthafa, N. Madhavan, B. P. Ajith Kumar, Rohit Sandal, K. M. Varier, B. R. S. Babu, A. K. Sinha, Reeshu Singh, Bency John, Sunil Kalkal, R. G. Thomas, J. Gehlot, Akhil Jhingan
Publikováno v:
Physical Review C. 81
Fission fragment mass ratio distributions have been measured for the reactions $^{16}\mathrm{O}+^{194}\mathrm{Pt}$ and $^{24}\mathrm{Mg}+^{186}\mathrm{W}$, both leading to the same compound nucleus, $^{210}\mathrm{Rn}$, at near-barrier energies. The
Autor:
H. G. Rajprakash, K. Mahata, S. Kailas, Raison Thomas, B. P. Ajith Kumar, B. V. John, A. Saxena, K. M. Varier
Publikováno v:
Physical Review C. 73
Autor:
R. G. Thomas, B. P. Ajith Kumar, K. M. Varier, H. G. Rajprakash, S. Kailas, K. Mahata, A. Saxena, B. V. John
Publikováno v:
Physical Review C. 72
Fission fragment anisotropies and fusion cross sections were measured for {sup 13}C+{sup 232}Th in the energy range 0.9 {alpha}{sub BG}). It is found that the observed anisotropies are much closer to that of the {sup 12}C+{sup 232}Th system.
Publikováno v:
Review of Scientific Instruments. 77:096102
CAMAC standard crates and modules continue to be used for nuclear and high energy physics experiments and test setups. They provide unbeaten performance in high precision measurements, flexibility and simplicity in the design of modules. We have desi