Zobrazeno 1 - 10
of 13
pro vyhledávání: '"B. Lutkenhoner"'
Autor:
B. Lutkenhoner
Publikováno v:
IEEE Transactions on Biomedical Engineering. 45:572-581
By studying the ability of a one-dipole model to explain the magnetic field actually resulting from two dipoles, minimum requirements for a successful separation of two dipoles were explored. Two dipoles in different depths generally require a much h
Autor:
B. Lutkenhoner
Publikováno v:
Electroencephalography and Clinical Neurophysiology. 106:314-321
By analyzing simulated neuromagnetic recordings with a 37 channel magnetometer system, it was shown that the accuracy of a dipole source localization is considerably improved if the standard least-squares fit procedure is replaced by a maximum likeli
Publikováno v:
Brain Topography. 9:117-124
This paper introduces the concept of the resolution matrix as the basis for an objective theoretical comparison of distributed linear inverse solutions to the neuroelectromagnetic inverse problem. In particular, we describe how figures of merit deriv
Autor:
B. Lutkenhoner
Publikováno v:
Electroencephalography and clinical neurophysiology. 106(4)
A dipole source analysis of repeated measurements of the auditory evoked field (AEF) elicited by 60 dB SL tonebursts confirmed the previous theoretical prediction that a maximum likelihood estimation technique reduces localization errors resulting fr
Publikováno v:
Electroencephalography and clinical neurophysiology. 102(4)
The concept of a resolution field provides a means to compare arbitrary estimators of a brain activity of interest (AOI), represented, for example, by the amplitude of a dipole at a certain location of interest with well-defined and known direction.
Autor:
B. Lutkenhoner
Publikováno v:
IEEE transactions on bio-medical engineering. 43(11)
The goal of the study was to explore the most fundamental aspects of a magnetoencephalography (MEG)-based dipole source analysis. For that purpose, a MEG measurement with an ideal magnetometer system (providing the radial component of the magnetic fi
Publikováno v:
IEEE transactions on bio-medical engineering. 41(10)
The dependence of the neuromagnetic source localization accuracy on the volume conductor model was studied by the analysis of measured magnetic fields generated by tangentially oriented dipoles in a realistically shaped skull phantom. When using a ho
Publikováno v:
International Journal of Audiology. 23:195-205
A new method of filtering auditory brain stem responses (ABR), which is time-and intensity-dependent, is proposed. The epoch containing the averaged response is divided up into 128 overlapping segments and each segment is differently filtered. The ch
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.