Zobrazeno 1 - 10
of 156
pro vyhledávání: '"B. J. Gerbi"'
Publikováno v:
Journal of neuro-oncology. 40(1)
In this study we evaluate prognostic factors that predict local-regional control and survival following stereotactic radiosurgery (SRS) in patients with brain metastasis and establish guidelines for patient selection. Our evaluation is based on 73 pa
Publikováno v:
Physics in medicine and biology. 43(10)
A new dosimetric quantity, the lateral build-up ratio (LBR), has been introduced to calculate depth dose distribution for any shaped field. Factors to account for change in incident fluence with collimation are applied separately. The LBR data for a
Publikováno v:
Medical Physics; Dec2003, Vol. 30 Issue 12, p3118-3123, 6p
Autor:
B J, Gerbi
Publikováno v:
Medical physics. 18(4)
Obtaining accurate %DD values for routine treatment calculations is essential in radiation therapy. Many papers have presented expressions to calculate this or related parameters but these expressions often required that the parameters needed by the
Autor:
B J, Gerbi, F M, Khan
Publikováno v:
Medical physics. 17(1)
Accurate measurement of dose at the surface of a phantom and in the buildup region is a difficult task but one that is important for the proper treatment of patients. The instruments of choice for these measurements are extrapolation chambers but few
Autor:
R A Potish, B J Gerbi
Publikováno v:
Radiology. 165:555-560
Dose and volume specifications for reporting intracavitary therapy were analyzed according to criteria recommended by the International Commission on Radiation Units and Measurements (ICRU). Ninety Fletcher-Suit radium applications were studied to ex
Autor:
Trout, Kevin L.1 (AUTHOR), Majumdar, Sanghamitra1 (AUTHOR), Patri, Anil K.1 (AUTHOR), Fahmi, Tariq1 (AUTHOR)
Publikováno v:
Nanotoxicology. Feb2023, Vol. 17 Issue 1, p116-142. 27p.
Autor:
B J, Gerbi, S H, Levitt
Publikováno v:
Frontiers of radiation therapy and oncology. 21
Autor:
B J, Gerbi
Publikováno v:
Medical physics. 12(5)
This paper describes a method of designing 3-dimensional compensating filters for radiation therapy using photon beams. A radiopaque grid is placed on the patient surface and stereo shift radiographs are taken of the treatment area. With the aid of a
Autor:
B J, Gerbi, F M, Khan
Publikováno v:
Medical physics. 14(2)
The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-03