Zobrazeno 1 - 10
of 22
pro vyhledávání: '"B. F. Hochheimer"'
Autor:
B. F. Hochheimer, Henry A. Kues
Publikováno v:
Applied optics. 21(21)
Retinal photographs taken with crossed polarizers in the input and recording light paths show a cross or brush pattern overlying the macula. Experiments were done indicating that this pattern is due to the birefringence in cone-photoreceptor outer se
Autor:
B. F. Hochheimer
Publikováno v:
Applied optics. 16(8)
Autor:
B. F. Hochheimer
Publikováno v:
Applied optics. 5(1)
A Michelson interferometer has been used to measure the visibility curves for the 6328 A neon emission line in a 90% He-10% Ne gas mixture in order to determine the effect of an optical cavity upon the line shape when the medium exhibits a net gain a
Autor:
B. F. Hochheimer
The general objective of this program is to document changes in the retina due to very low level laser irradiation. We had two primary aims. One was to develop and improve methods that can be used, in vivo, to objectively determine changes that occur
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::bdd1667181584c6ac171035bd39a6912
https://doi.org/10.21236/ada227521
https://doi.org/10.21236/ada227521
Publikováno v:
Investigative ophthalmologyvisual science. 21(2)
Double-exposure holograms are taken of the patient's cornea after a heartbeat. The resulting stress test, or holographic interferogram, shows sharply demarcated fringe patterns outlining structurally weak areas in the cornea. Wound strength in postop
Autor:
J L, Calkins, B F, Hochheimer
Publikováno v:
Investigative ophthalmologyvisual science. 19(9)
The projected beam radiance of several common ophthalmologic instruments was measured, and potential hazard to the patient from light exposure was analyzed with reference to safety standards for coherent light. The indirect ophthalmoscopes tested app
Autor:
R W, Flower, B F, Hochheimer
Publikováno v:
The Johns Hopkins medical journal. 138(2)
The sensory retina of the eye is nourished by two essentially separate blood circulations. The more superficial of these, the retinal circulation, is easily evaluated by direct visualization or routine fluorescein angiography. However, the underlying
Autor:
B F, Hochheimer, R W, Flower
Publikováno v:
The Johns Hopkins medical journal. 135(6)
Autor:
B F, Hochheimer
Publikováno v:
Journal of the Biological Photographic Association. 45(4)
Autor:
B. F. Hochheimer, J. L. Calkins
Publikováno v:
Optical Engineering. 16
The integrated radiance of several types of flashbulbs has been measured and compared with the maximum permissible exposure for published laser standards. At close distances several flashbulb types have integrated radiance values that exceed those al