Zobrazeno 1 - 10
of 139
pro vyhledávání: '"B Rangert"'
Autor:
Brook, I.M.
Publikováno v:
In British Journal of Oral & Maxillofacial Surgery 2008 46(8):698-698
Publikováno v:
International Journal of Oral and Maxillofacial Surgery. 26:141-148
The influence of diameter on the integration of titanium screw-shaped implants was studied in the rabbit tibia by means of removal torque measurements and histomorphometry. Implants 3.0, 3.75, 5.0, and 6.0 mm in diameter and 6.0 mm long were inserted
Publikováno v:
Clinical Oral Implants Research. 7:55-63
In a combined in vitro and in vivo study strain gauges were used to register the deformation in two terminal implant abutment cylinders, when connecting three different prosthetic appliances. The prosthetic constructions were placed on the abutments
Publikováno v:
Clinical Oral Implants Research. 6:40-46
In vivo bite forces, implant axial forces and bending moments were measured on 5 patients with fixed posterior prostheses supported by a natural tooth and a single Brinemark implant. The results demonstrate that the vertical loads applied to the pros
Autor:
B Rangert, G D Stafford, Hultén J, P O Glantz, B Arnvidarson, Kjell Randow, U Lindén, A. Svensson
Publikováno v:
Clinical Oral Implants Research. 4:99-105
Strain gauges were used to record in vivo and in vitro functional deformations in a fixed prosthetic appliance supported and retained by osseointegrated titanium implants. Four linear gauges were attached to each of totally 5 implant abutment cylinde
Publikováno v:
The International journal of oralmaxillofacial implants. 15(3)
Rehabilitation of atrophied edentulous arches with endosseous implants in the posterior regions is often associated with anatomic problems such as jaw shape and location of the mental loop, mandibular canal, and maxillary sinuses. The purpose of this
Publikováno v:
The International journal of oralmaxillofacial implants. 12(3)
In vivo measurements of vertical forces and bending moments during biting and chewing were carried out on 10 three-unit prostheses in the posterior mandibles of five patients. Each patient had two prostheses, one supported by two implants and the oth
Publikováno v:
International journal of oral and maxillofacial surgery. 26(2)
The influence of diameter on the integration of titanium screw-shaped implants was studied in the rabbit tibia by means of removal torque measurements and histomorphometry. Implants 3.0, 3.75, 5.0, and 6.0 mm in diameter and 6.0 mm long were inserted
Publikováno v:
The International journal of oralmaxillofacial implants. 11(3)
A comparative study between one and two Brånemark implants replacing a single molar was conducted. Forty-seven individuals comprised two groups of 22 patients treated with one implant and 25 with two implants. A total of 72 implants were placed, 66
Publikováno v:
Clinical oral implants research. 7(1)
In a combined in vitro and in vivo study strain gauges were used to register the deformation in two terminal implant abutment cylinders, when connecting three different prosthetic appliances. The prosthetic constructions were placed on the abutments