Zobrazeno 1 - 10
of 36
pro vyhledávání: '"B M, Alving"'
Publikováno v:
Vox Sanguinis. 75:270-277
Publikováno v:
Blood Coagulation & Fibrinolysis. 7:737-746
There are few well-controlled studies of the clinical efficacy of fibrin sealant, defined by lives saved or reduced need for blood transfusions. Evaluation of fibrin sealant in trauma situations, e.g. liver laceration, has been difficult to perform.
Publikováno v:
Blood. 82:3631-3636
The role of defective fibrinolysis caused by elevated activity of plasminogen activator inhibitor-1 (PAI-1) in promoting fibrin deposition in vivo has not been well established. The present study compared the efficacy of thrombin or ancrod, a venom-d
Autor:
D Menache, M. B. Hultin, J. P. Ómalley, C. Williams, W. E. Hathaway, J. O. Ballard, B. Wagner, B. M. Alving, J. B. Schorr, S. H. Goodnight
Publikováno v:
Blood. 75:33-39
Antithrombin III (Human) (AT III) was administered to 18 patients with documented hereditary AT III deficiency. In eight patients with no ongoing clinical symptoms of thrombosis, the percent increase per unit AT III infused per kilogram of body weigh
Autor:
J. A. Penner, B. Wagner, C. S. Kitchens, S. H. Goodnight, J. O. Ballard, J. P. Ómalley, J. E. Sanders, Marilyn J. Manco-Johnson, J. B. Schorr, M. B. Hultin, W. G. Mcgehee, B. M. Alving, W. E. Hathaway, H. E. Lessner, D Menache, C. Williams, A. Z. Makary
Publikováno v:
Blood. 75:33-39
Antithrombin III (Human) (AT III) was administered to 18 patients with documented hereditary AT III deficiency. In eight patients with no ongoing clinical symptoms of thrombosis, the percent increase per unit AT III infused per kilogram of body weigh
Autor:
B M, Alving
Publikováno v:
Journal of thrombosis and thrombolysis. 12(1)
The antiphospholipid syndrome is an autoimmune disorder characterized by venous or arterial thrombosis, recurrent pregnancy loss, and thrombocytopenia combined with laboratory tests that indicate the presence of antibodies against phospholipid-bindin
Publikováno v:
Vox sanguinis. 75(4)
The changes that occur in platelets as they undergo storage have been documented by aggregometry as well as by flow cytometry. However, one of the most essential platelet functions, the induction of clot retraction, has not been quantitatively assess
Publikováno v:
The Journal of trauma. 45(4)
Objective: The purpose of this study is to determine the hemostatic efficacy of a fibrin sealant dressing compared with a standard collagen control dressing in an animal model of kidney injury. Methods: Twenty adult male Sprague-Dawley rats were admi
Publikováno v:
Blood coagulationfibrinolysis : an international journal in haemostasis and thrombosis. 7(8)
There are few well-controlled studies of the clinical efficacy of fibrin sealant, defined by lives saved or reduced need for blood transfusions. Evaluation of fibrin sealant in trauma situations, e.g. liver laceration, has been difficult to perform.
Autor:
Marcus E. Carr, B. M. Alving
Publikováno v:
Blood coagulationfibrinolysis : an international journal in haemostasis and thrombosis. 6(6)
Previous studies in purified systems have demonstrated that fibrin structure influences the rate of conversion of plasminogen to plasmin by t-PA as well as the rate of plasmin-mediated clot digestion. The present study extended these observations to