Zobrazeno 1 - 10
of 16
pro vyhledávání: '"B L, Wilkoff"'
Autor:
C Kennergren, J E Poole, B L Wilkoff, S Mittal, G R Corey, J Mccomb, I Diemberger, D J Wright, B T Philbert, T A Simmers, L V A Boersma, B Debus, J Krueger, K Vandersteegen, K G Tarakji
Publikováno v:
EP Europace. 22
Funding Acknowledgements Medtronic, Inc. Introduction Cardiac Implantable Electronic Device (CIED) infections lead to significant morbidity, mortality, and use of health care resources. There is variation in infection prevention strategies among cent
Publikováno v:
Cleveland Clinic Journal of Medicine. 65:159-166
Amiodarone is a potent and versatile antiarrhythmic. Despite side effects involving the lungs, heart, thyroid, and other organs, it is effective in the treatment of refractory atrial and ventricular arrhythmias and it has unique safety in patients wi
Autor:
B L Wilkoff, J R Gimbel
Publikováno v:
Heart (British Cardiac Society). 89(3)
An implantable loop recorder (ILR) was implanted in a 45 year old man with recurrent syncope. A subsequent episode of injurious syncope led to performance of a cranial and shoulder magnetic resonance imaging (MRI). An artefact mimicking both wide and
Autor:
A P, Hallstrom, J H, McAnulty, B L, Wilkoff, D, Follmann, M H, Raitt, M D, Carlson, A M, Gillis, H T, Shih, J L, Powell, H, Duff, B D, Halperin
Publikováno v:
Journal of the American College of Cardiology. 37(4)
The goal of this study was to identify subgroups of arrhythmia patients who do not benefit from use of the implantable cardiac defibrillator (ICD).Treatment of serious ventricular arrhythmias has evolved toward more common use of the ICD. Since estim
Autor:
S, Pavia, B L, Wilkoff
Publikováno v:
Cleveland Clinic journal of medicine. 68(2)
The Multicenter Unsustained Tachycardia Trial (MUSTT) demonstrated that electrophysiologic testing (EP)-guided therapy significantly reduces arrhythmic death and cardiac arrest in patients with coronary artery disease, a left ventricular ejection fra
Autor:
C, Kennergren, R H, Schaerf, T D, Sellers, B L, Wilkoff, C L, Byrd, G F, Tyres, S, Coe, C W, Coates, C, Reiser
Publikováno v:
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 4(4)
Extraction of chronically implanted pacing and defibrillator leads is facilitated by using specialized locking stylets placed in the lead to allow application of traction and to stabilize the lead during sheath dissection of fibrotic tissue. We repor
Autor:
C J, Love, B L, Wilkoff, C L, Byrd, P H, Belott, J A, Brinker, N E, Fearnot, R A, Friedman, S, Furman, L B, Goode, D L, Hayes, D T, Kawanishi, V, Parsonnet, C, Reiser, H J, Van Zandt
Publikováno v:
Pacing and clinical electrophysiology : PACE. 23(4 Pt 1)
The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the
Autor:
C L, Byrd, B L, Wilkoff, C J, Love, T D, Sellers, K T, Turk, R, Reeves, R, Young, B, Crevey, S P, Kutalek, R, Freedman, R, Friedman, J, Trantham, M, Watts, J, Schutzman, J, Oren, J, Wilson, F, Gold, N E, Fearnot, H J, Van Zandt
Publikováno v:
Pacing and clinical electrophysiology : PACE. 22(9)
Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved
Autor:
M K, Chung, R A, Schweikert, B L, Wilkoff, M J, Niebauer, S L, Pinski, R G, Trohman, G A, Kidwell, F J, Jaeger, V A, Morant, D P, Miller, P J, Tchou
Publikováno v:
Journal of the American College of Cardiology. 32(1)
We sought to determine the yield of in-hospital monitoring for detection of significant arrhythmia complications in patients starting sotalol therapy for atrial arrhythmias and to identify factors that might predict safe outpatient initiation.The nee
Publikováno v:
Exercise and sport sciences reviews. 25
Patients with malignant arrhythmias are a challenge when they present to the laboratory for exercise testing and training. The complex metabolic and electrophysiological changes that occur during and after exercise may suppress or potentiate arrhythm