This study aimed to evaluate the property of small dosimeters used for measuring eye lens doses for medical staff during fluoroscopic examination. Dose linearity, energy dependence, and directional dependence of scattered X-rays were evaluated for sm
Externí odkaz:
https://doaj.org/article/b4fb819f706d4d72b69d4b0bbc89ab7e
Autor:
Akihiro Takemura, Yusuke Morioka, Thunyarat Chusin, Kosuke Matsubara, Ayaka Hirosawa, Masayasu Kitagawa
Publikováno v:
Physical and Engineering Sciences in Medicine. 44:1311-1319
We aimed to evaluate properties of optically stimulated luminescence dosimeters (OSLDs) and radiophotoluminescent glass dosimeters (RPLDs) used in dual-source dual-energy (DE) computed tomography (DECT) dosimetry. Energy dependence was evaluated in s
Publikováno v:
Diagnostics
Diagnostics, Vol 11, Iss 150, p 150 (2021)
Diagnostics; Volume 11; Issue 2; Pages: 150
Diagnostics, Vol 11, Iss 150, p 150 (2021)
Diagnostics; Volume 11; Issue 2; Pages: 150
This study aimed to evaluate the property of small dosimeters used for measuring eye lens doses for medical staff during fluoroscopic examination. Dose linearity, energy dependence, and directional dependence of scattered X-rays were evaluated for sm
Publikováno v:
Nihon Hoshasen Gijutsu Gakkai zasshi. 76(1)
It is important to reduce the dose received by medical staffs. The purpose of this study was to evaluate the effect of protective curtain and the property of small optically stimulated luminescence (OSL) dosimeters used for ambient dose measurement i
Evaluation of Time Delay and Fluoroscopic Dose in a New Real-Time Tumor-Tracking Radiotherapy System
Publikováno v:
IFMBE Proceedings ISBN: 9789811090226
A combined system comprising the LINIAC TrueBeam (Varian Medical Systems, Palo Alt, CA) and a new real-time tumor-tracking radiotherapy system, SyncTraX FX4® (Shimadzu Co., Kyoto, Japan), was installed in our institution. It consists of four pairs o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::11f4df0ba494b2f7055af7f76b116ebb
https://doi.org/10.1007/978-981-10-9023-3_88
https://doi.org/10.1007/978-981-10-9023-3_88
Publikováno v:
Japanese Journal of Radiological Technology. 71:12-18
There are two types of radiophotoluminescent glass dosimeters (RPLDs). One has a tin filter in the capsule (GD-352M) and the other has no filter (GD-302M). The purpose of our study was to evaluate the properties of these RPLDs for computed tomography
Publikováno v:
Journal of Japan Institute of Light Metals. 64:63-67
Publikováno v:
Journal of Applied Clinical Medical Physics
Determination of the half‐value layer (HVL) and quarter‐value layer (QVL) values is not an easy task in X‐ray computed tomography (CT), because a nonrotating X‐ray tube must be used, which requires the assistance of service engineers. Therefo
Autor:
Kosuke Matsubara, Rena Okubo, Thunyarat Chusin, Ayaka Hirosawa, Yoshinori Ogawa, Hiroji Nagata
Publikováno v:
Journal of Physics: Conference Series. 1248:012020
We aimed to validate Monte Carlo (MC) simulation models against measurements and evaluate the effect of object size on axial absorbed dose distributions during abdominal computed tomography (CT) acquisitions based on MC simulations. A medium-sized ab