Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Axel Kolling"'
Autor:
Axel Kolling
Publikováno v:
kma - Klinik Management aktuell. 26:51-52
Ein Konsortium aus Wissenschaft und Medizintechnik entwickelt ein technisches System, das im Operationssaal automatisch für die optimale Beleuchtung sorgen soll. Es kompensiert Schattenwürfe, die durch Bewegungen des OP-Teams entstehen, und lässt
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 66:1531-1538
This paper presents an improved calibration setup for static bridge standards with a carrier frequency supply voltage in the frequency range between 225 Hz and 5 kHz. In the past, the small bridge differential voltage in the mV/V range was calibrated
Publikováno v:
2018 Conference on Precision Electromagnetic Measurements (CPEM 2018).
We present a setup for linearity investigation of high precision bridge amplifiers as used for strain gauge transducer in static force and torque measurements. The setup allows to characterize bridge amplifiers in much more detail than the 0.1m V/V s
Publikováno v:
Funck, T, Bothe, H, Kölling, A, Satrapinski, A & Suomalainen, E-P 2017, ' Bilateral international inductance comparison using traveling standards in thermoregulated enclosures ', IEEE Transactions on Instrumentation and Measurement, vol. 66, no. 6, 7801843, pp. 1511-1515 . https://doi.org/10.1109/TIM.2016.2634720
Funck, T, Bothe, H, Kolling, A, Satrapinski, A & Suomalainen, E-P 2016, Bilateral international inductance comparison using traveling standards in thermoregulated enclosures . in 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) ., 7540510, IEEE Institute of Electrical and Electronic Engineers, Conference on Precision Electromagnetic Measurements, CPEM 2016, Ottawa, Canada, 10/07/16 . https://doi.org/10.1109/CPEM.2016.7540510
Funck, T, Bothe, H, Kolling, A, Satrapinski, A & Suomalainen, E-P 2016, Bilateral international inductance comparison using traveling standards in thermoregulated enclosures . in 2016 Conference on Precision Electromagnetic Measurements (CPEM 2016) ., 7540510, IEEE Institute of Electrical and Electronic Engineers, Conference on Precision Electromagnetic Measurements, CPEM 2016, Ottawa, Canada, 10/07/16 . https://doi.org/10.1109/CPEM.2016.7540510
Standards with toroidal windings are traditionally used for international comparisons of inductance. The achieved uncertainties of the comparisons are dominated by the rather high temperature coefficient of the traveling standards. Hence, thermoregul
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c595069ad987ed3eed60ac10c0f46fdc
https://doi.org/10.1109/CPEM.2016.7540510
https://doi.org/10.1109/CPEM.2016.7540510
Publikováno v:
2016 Conference on Precision Electromagnetic Measurements (CPEM 2016).
This paper presents an improved calibration setup for static bridge standards with carrier frequency supply voltage in the frequency range between 225 Hz and 5 kHz. In the past the small bridge differential voltage in the mV/V range was calibrated in
Publikováno v:
Journal of Physics: Conference Series. 1065:042010