Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Augusto Carimatto"'
Autor:
Augusto Carimatto, Edoardo Charbon
Publikováno v:
Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues XIX.
We present the first image sensor that, equipped with a matrix of 64x64 SPADs and a 4-layers distributed artificial neural network (ANN), can be ”reprogrammed” (by loading its weights) at run-time to perform any required task without redesigning
Autor:
Augusto Carimatto, Juan Alarcon, Esteban Venialgo, Daniel S. Estryk, Martin A. Belzunce, Elias da Ponte, Claudio Verrastro, Isaac Marcos Cohen, Lucio Martinez Garbino
Publikováno v:
IEEE Transactions on Nuclear Science. 61:975-984
Tomographic Gamma Scanners are tools for nondestructive assay and characterization of nuclear waste drums. In these scanners, a three dimensional image of the activity distribution of every radioisotope stored in the drum is obtained by performing a
Autor:
Shingo Mandai, Ting Gong, Augusto Carimatto, Esteban Venialgo, Dennis R. Schaart, Giacomo Borghi, Edoardo Charbon
Publikováno v:
ISSCC
Positron emission tomography (PET) is a medical imaging technique for non-invasive detection of glucose metabolism in human organs, such as the brain, heart, and lungs. A positron-emitting molecule, generally Fluorodeoxyglucose-18 (18F-FDG), is injec
Publikováno v:
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
The endoscopic time-of-flight positron emission tomography concept implemented in an ultrasonic probe requires an ultra-miniaturized optical sensor capable of detecting single and multiple photons with high timing resolution. Due to the extreme level
Autor:
Elias da Ponte, Esteban Venialgo, Lucio Martinez Garbino, Augusto Carimatto, Daniel S. Estryk, Juan Alarcon, Martin A. Belzunce, Claudio Verrastro
Publikováno v:
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).
Tomographic Gamma Scanners are novels tools for nondestructive assay and characterization of nuclear waste drums. In these scanners, a three dimensional image of the activity distribution of every radioisotope stored in the drum is obtained performin
Autor:
Lucio Martinez Garbino, Elias da Ponte, Martin A. Belzunce, Augusto Carimatto, Daniel S. Estryk, Isabel Prieto, Claudio Verrastro, Esteban Venialgo, Juan Alarcon
Publikováno v:
MRS Proceedings. 1475
In recent years, nuclear waste management has become a fundamental issue in the nuclear energy production cycle. Tomographic Gamma Scanner (TGS) is an essential tool for nuclear waste characterization. It is crucial to rely on local support and cost
Autor:
Juan Alarcon, E. da Ponte, Martin A. Belzunce, Claudio Verrastro, Augusto Carimatto, Esteban Venialgo, L. J. Martinez Garbino, Daniel S. Estryk
Publikováno v:
2011 IEEE Nuclear Science Symposium Conference Record.
This paper presents a calibration method for obtaining data to adjust nonlinear position estimation algorithms. This procedure is based on two measurements utilizing specialized collimators and a background subtraction algorithm. Since this method do
Autor:
Shingo Mandai, Edoardo Charbon, S. Sinha, T. Gong, Dennis R. Schaart, Esteban Venialgo, Stephan Brunner, Augusto Carimatto
Publikováno v:
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
In time-of-flight (TOF) positron emission tomography (PET), the coincidence resolving time (CRT) has a strong influence on the overall performance. Multichannel digital silicon photomultipliers (MD-SiPMs) are able to obtain several timestamps for gam
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6ff8b322370ac63681f034350d42f2d3
https://infoscience.epfl.ch/record/256483
https://infoscience.epfl.ch/record/256483