Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Audren Boulme"'
Autor:
Valentin Goepfert, Audren Boulmé, Franck Levassort, Tony Merrien, Rémi Rouffaud, Dominique Certon
Publikováno v:
Micromachines, Vol 14, Iss 11, p 2089 (2023)
A complete model was developed to simulate the behavior of a circular clamped axisymmetric fluid-coupled Piezoelectric Micromachined Ultrasonic Transducer (PMUT). Combining Finite Difference and Boundary Element Matrix (FD-BEM), this model is based o
Externí odkaz:
https://doaj.org/article/80d2238b11b14b0fb2bb6073b8597a84
Publikováno v:
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control. 2:162-172
Publikováno v:
2021 IEEE International Ultrasonics Symposium (IUS)
2021 IEEE International Ultrasonics Symposium (IUS), Sep 2021, Xi'an, China. pp.1-4, ⟨10.1109/IUS52206.2021.9593399⟩
2021 IEEE International Ultrasonics Symposium (IUS), Sep 2021, Xi'an, China. pp.1-4, ⟨10.1109/IUS52206.2021.9593399⟩
International audience; The main challenge with Capacitive Micromachined Ultrasonic Transducer (CMUT) probes packaging is to preserve their intrinsic performances. Indeed, careful attention should be paid to the encapsulation of CMUTs and the impact
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::cd68309b8e6f34076899e56be654dbea
https://hal.archives-ouvertes.fr/hal-03454536
https://hal.archives-ouvertes.fr/hal-03454536
Autor:
Dominique Certon, Tony Mateo, Maxime Hery, Audren Boulme, Dominique Gross, Cyril Meynier, Nicolas Senegond
Publikováno v:
2018 IEEE International Ultrasonics Symposium (IUS).
This work is an experimental validation of a new approach to design and to optimize the response of CMUT -based linear arrays. The method is applied to the design of linear arrays centered at 10 MHz. Two configurations, with two different spectral si
Publikováno v:
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2018, 65 (4), pp.617-629. ⟨10.1109/TUFFC.2018.2796303⟩
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2018, 65 (4), pp.617-629. ⟨10.1109/TUFFC.2018.2796303⟩
This paper presents the development of a novel acoustic transformer with high galvanic isolation dedicated to power switch triggering. The transformer is based on two capacitive micromachined ultrasonic transducers layered on each side of a silicon s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::df98bbceabb87997b1b0577bc6b6d7ab
https://hal-univ-tours.archives-ouvertes.fr/hal-02123675
https://hal-univ-tours.archives-ouvertes.fr/hal-02123675
Publikováno v:
Physics Procedia. 70:992-996
This paper describes the implementation of a new equivalent electroacoustic circuit for cMUT arrays. This circuit was obtained by using the normal mode theory. Theoretical simulations were also carried out from this new circuit to illustrate the impa
Publikováno v:
Physics Procedia. 70:987-991
This paper describes a new way of using cMUT technology: galvanic isolation for power electronics. These devices work like acoustic transformers, except that piezoelectricity is replaced by cMUT technology. Primary and secondary circuits are two cMUT
Autor:
Ludovic Pasquet, Tony Mateo, Nicolas Senegond, Cyril Meynier, Dominique Certon, Dominique Gross, Audren Boulme
Publikováno v:
2017 IEEE International Ultrasonics Symposium (IUS).
Among the different transducers technologies suitable for medical imaging, the cMUTs are known to offer an attractive alternative to conventional piezoelectric ones, with features including wider bandwidth, wider directivity, and readiness for integr
Autor:
Christopher Bawiec, W. Apoutou N'Djin, Nicolas Senegond, Dominique Gross, Audren Boulme, Dominique Certon
Publikováno v:
2017 IEEE International Ultrasonics Symposium (IUS).
Even though the CMUT technology is currently experiencing an exciting era in the field of ultrasonic imaging, few studies have assessed the real interest of this technology for therapeutic purposes compared to the state-of-the-art technology. Moreove
Autor:
Dominique Certon, Audren Boulme, Pascal Laugier, Jean-Gabriel Minonzio, Maryline Talmant, Sophie Ngo, Mathieu Legros
Publikováno v:
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2014, 61 (4), pp.710-723. ⟨10.1109/TUFFC.2014.2959⟩
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2014, 61 (4), pp.710-723. ⟨10.1109/TUFFC.2014.2959⟩
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2014, 61 (4), pp.710-723. ⟨10.1109/TUFFC.2014.2959⟩
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2014, 61 (4), pp.710-723. ⟨10.1109/TUFFC.2014.2959⟩
International audience; A wide range of ultrasound methods has been proposed to assess the mechanical strength of bone. Axial transmission technique, which consists of measuring guided elastic modes through the cortical shell of long bones such as th