Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Arturo Carratala Calvo"'
Autor:
Inmaculada Vinyals-Bellido, Adela Pozo-Giraldez, Ausias Hervas-Romero, Arturo Carratala Calvo, Africa Corchon-Peyrallo, Macarena Diaz-Gimenez, Enrique Rodriguez-Borja
Publikováno v:
Biochemia Medica
Volume 31
Issue 2
Volume 31
Issue 2
Introduction An appropriate management of anaemia laboratory tests is crucial for a correct diagnosis and treatment. A non-sequential "shotgun" approach (where every anaemia related test is ordered) causes workload and cost increases and could be pot
Autor:
Macarena Diaz-Gimenez, Adela Pozo-Giraldez, Arturo Carratala-Calvo, Jaume Perez-Griera, Enrique Rodriguez-Borja, Pablo Magro-Pose
Publikováno v:
CLINICAL BIOCHEMISTRY
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
BACKGROUND: Anti-Sry-like high mobility group box 1 (anti SOX-1) proteins are rare onconeural antibodies associated with paraneoplastic Lambert-Eaton myasthenic syndrome (LEMS). Few patients with anti-SOX-1 antibodies and negative anti-glial nuclear
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ceb7d6591eaa1a66ac05a9e338349a6e
https://www.fundanet.incliva.es/publicaciones/ProdCientif/PublicacionFrw.aspx?id=16071
https://www.fundanet.incliva.es/publicaciones/ProdCientif/PublicacionFrw.aspx?id=16071
Autor:
Celia Villalba Martínez, Arturo Carratala Calvo, Africa Corchon-Peyrallo, Enrique Rodriguez-Borja, Esther Barba-Serrano
Publikováno v:
Clinical Chemistry and Laboratory Medicine (CCLM). 56:1063-1070
Background: We assessed the impact of several “send & hold” clinical decision support rules (CDSRs) within the electronical request system for vitamins A, E, K, B1, B2, B3, B6 and C for all outpatients at a large health department. Methods: When
Autor:
Esther Barba-Serrano, Celia Villalba-Martinez, Enrique Rodriguez-Borja, Arturo Carratala-Calvo
Publikováno v:
Biochemia Medica
Volume 26
Issue 1
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Volume 26
Issue 1
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Background: Failure to follow-up laboratory test results has been described as one of the major processes contributing to unsafe patient care. Currently, most of the laboratories do not know with certainty not only their rate of missed (or unreviewed
Autor:
Arturo Carratala-Calvo, Enrique Rodriguez-Borja, Macarena Diaz-Gimenez, Africa Corchon-Peyrallo
Publikováno v:
Biochemia Medica
Volume 28
Issue 3
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Volume 28
Issue 3
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Introduction Most of clinical laboratories are not properly reimbursed for their activity related to clinical trials (CTs) conducted in their institutions due to a lack of measurement strategies. We implemented a specific computer physician order ent
Autor:
Enrique Rodriguez-Borja, Arturo Carratala-Calvo, Gerardo Aguilar-Aguilar, Africa Corchon-Peyrallo
Publikováno v:
Biochemia Medica
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Volume 27
Issue 3
r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname
Volume 27
Issue 3
Introduction The usefulness and cost-effectiveness of routine laboratory preoperative tests (POTs) have been challenged recently. In fact, the American Society of Anesthesiologists (ASA) Task Force has stated that test results obtained from the medic
Publikováno v:
Journal of Clinical Pathology. 67:642-644
Background Traditionally, laboratories’ turnaround times (TAT) have been calculated by only considering analytical or intralaboratory steps. The measure of the postanalytical impact in TAT has barely been studied and, more specifically, the running