Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Arnaud Diffo Kaze"'
Autor:
Arnaud Diffo Kaze, Stefan Maas, James Belsey, Alexander Hoffmann, Romain Seil, Ronald van Heerwaarden, Dietrich Pape
Publikováno v:
Journal of Experimental Orthopaedics, Vol 6, Iss 1, Pp 1-15 (2019)
Abstract Background This study aimed to assess the mechanical static and fatigue strength provided by the FlexitSystem plate in medial opening wedge high tibial osteotomies (MOWHTO), and to compare it to six previously tested implants: the TomoFix sm
Externí odkaz:
https://doaj.org/article/2743b47a0ef8496594d319411f50f6cb
Autor:
James Belsey, Arnaud Diffo Kaze, Simon Jobson, James Faulkner, Stefan Maas, Raghbir Khakha, Adrian J. Wilson, Dietrich Pape
Publikováno v:
Journal of Experimental Orthopaedics, Vol 6, Iss 1, Pp 1-9 (2019)
Abstract Background The purpose of this study was to compare the stability of medial opening-wedge high tibial osteotomy (MOWHTO) with and without different graft materials. Good clinical and radiological outcomes have been demonstrated when either u
Externí odkaz:
https://doaj.org/article/9f8e2bd2f64942d7a12eb21682080443
Autor:
Arnaud Diffo Kaze, Stefan Maas, Slawomir Kedziora, James Belsey, Alexander Haupert, Claude Wolf, Alexander Hoffmann, Dietrich Pape
Publikováno v:
Journal of Experimental Orthopaedics, Vol 5, Iss 1, Pp 1-17 (2018)
Abstract Background Many different fixation devices are used to maintain the correction angle after medial open wedge high tibial osteotomy (MOWHTO). Each device must provide at least sufficient mechanical stability to avoid loss of correction and un
Externí odkaz:
https://doaj.org/article/0de0950bf1fe4df3b44d1ad77282b228
Publikováno v:
Journal of Experimental Orthopaedics, Vol 4, Iss 1, Pp 1-13 (2017)
Abstract Background The purpose of the present study was to compare the mechanical static and fatigue strength of the size 2 osteotomy plate “Activmotion” with the following five other common implants for the treatment of medial knee joint osteoa
Externí odkaz:
https://doaj.org/article/f96397670335489caaee9ac9c4c7795f
Publikováno v:
BioMedical Engineering OnLine, Vol 16, Iss 1, Pp 1-19 (2017)
Abstract Background Results of finite element (FE) analyses can give insight into musculoskeletal diseases if physiological boundary conditions, which include the muscle forces during specific activities of daily life, are considered in the FE modell
Externí odkaz:
https://doaj.org/article/2fb845b903e548da8c2039ab31faa686
Publikováno v:
Journal of Experimental Orthopaedics, Vol 4, Iss 1, Pp 1-19 (2017)
Abstract Background This study aimed to investigate, by means of finite element analysis, the effect of a drill hole at the end of a horizontal osteotomy to reduce the risk of lateral cortex fracture while performing an opening wedge high tibial oste
Externí odkaz:
https://doaj.org/article/a99de09edbe543f198d559c8a2342cef
Autor:
James Belsey, Arnaud Diffo Kaze, Simon Jobson, James Faulkner, Stefan Maas, Raghbir Khakha, Dietrich Pape, Adrian J Wilson
Publikováno v:
PLoS ONE, Vol 14, Iss 5, p e0216660 (2019)
The inclusion of an allograft wedge during medial opening wedge high tibial osteotomy has been shown to lead to satisfactory time-to-union in larger corrections (>10°). Such large corrections are associated with greater incidences of intraoperative
Externí odkaz:
https://doaj.org/article/6aa72c4d042140aca9ae456b23e7577d
Publikováno v:
Journal of Experimental Orthopaedics, Vol 2, Iss 1, Pp n/a-n/a (2015)
Abstract Background As several new tibial osteotomy plates recently appeared on the market, the aim of the present study was to compare mechanical static and fatigue strength of three newly designed plates with gold standard plates for the treatment
Externí odkaz:
https://doaj.org/article/9906b5eb2f10423780445f5847615bbe
Publikováno v:
Journal of Experimental Orthopaedics, Vol 4, Iss 1, Pp 1-19 (2017)
Journal of Experimental Orthopaedics, 4(1). Heidelberg, Germany: SpringerOpen (2017).
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics, 4(1). Heidelberg, Germany: SpringerOpen (2017).
Journal of Experimental Orthopaedics
Background This study aimed to investigate, by means of finite element analysis, the effect of a drill hole at the end of a horizontal osteotomy to reduce the risk of lateral cortex fracture while performing an opening wedge high tibial osteotomy (OW
Autor:
Dietrich Pape, James Belsey, Ronald J van Heerwaarden, Stefan Maas, R. Seil, Arnaud Diffo Kaze, Alexander Hoffmann
Publikováno v:
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics, Vol 6, Iss 1, Pp 1-15 (2019)
Journal of Experimental Orthopaedics, Vol 6, Iss 1, Pp 1-15 (2019)
Background This study aimed to assess the mechanical static and fatigue strength provided by the FlexitSystem plate in medial opening wedge high tibial osteotomies (MOWHTO), and to compare it to six previously tested implants: the TomoFix small statu