Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Armand Rostamian"'
Autor:
Vijay Swarup, Tina Baykaner, James P. Daubert, John M. Miller, B S Rishi Trikha, Armand Rostamian, Gery F. Tomassoni, Sanjiv M. Narayan, David E. Krummen, John Hummel
Publikováno v:
Journal of Cardiovascular Electrophysiology. 25:1284-1292
Stable Human AF RotorsIntroduction Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that ex
Publikováno v:
Journal of Interventional Cardiac Electrophysiology. 40:63-74
Pulmonary vein isolation (PVI) during ablation of atrial fibrillation (AF) is associated with pulmonary vein stenosis (PVS). Although the reported incidence of PVS has fallen in recent years, the precise rate of PVS is unknown. Coherent guidelines fo
Publikováno v:
Echocardiography. 30:E239-E242
Platypnea-orthodeoxia is an uncommon syndrome characterized by positional dyspnea and hypoxia when upright that improves with lying down. We present a 75-year-old man with platypnea-orthodeoxia in the setting of a patent foramen ovale (PFO) and a 2.1
Autor:
Gautam G. Lalani, Michael Gibson, David E. Krummen, Sanjiv M. Narayan, Amir Schricker, Armand Rostamian
Publikováno v:
Journal of the American College of Cardiology. 59(6):595-606
Objectives The aim of this study was to determine whether onset sites of human atrial fibrillation (AF) exhibit conduction slowing, reduced amplitude, and/or prolonged duration of signals (i.e., fractionation) immediately before AF onset. Background
Publikováno v:
The American Journal of Cardiology. 106:893-901
Recent surveys and reports suggest that many athletes and bodybuilders abuse anabolic-androgenic steroids (AAS). However, scientific data on the cardiac and metabolic complications of AAS abuse are divergent and often conflicting. A total of 49 studi
Autor:
Vijay, Swarup, Tina, Baykaner, Armand, Rostamian, James P, Daubert, John, Hummel, David E, Krummen, Rishi, Trikha, John M, Miller, Gery F, Tomassoni, Sanjiv M, Narayan
Publikováno v:
Journal of cardiovascular electrophysiology. 25(12)
Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that examined only seconds of AF. We appli
Autor:
David E. Krummen, Sanjiv M. Narayan, Michael Gibson, Amir Schricker, Gautam G. Lalani, Armand Rostamian
Publikováno v:
Journal of the American College of Cardiology. (14):E87