Zobrazeno 1 - 10
of 29
pro vyhledávání: '"Arkadiusz Wasowski"'
Autor:
Arkadiusz Wasowski, Henryk Skarzynski, Artur Lorens, Anita Obrycka, Adam Walkowiak, Piotr Skarzynski, Andrzej Wlodarczyk, Lukasz Bruski
Publikováno v:
Journal of Hearing Science. 2:81-85
BackgroundTo obtain the best hearing benefits after cochlear implantation, the speech processor must be optimally fitted. The majority of patients have to undertake a long trip to the cochlear implant (CI) clinic, and this incurs high cost, time, and
Influence of Non-Optimal Levels of Electrical Stimulation in Cochlear Implantees on Hearing Benefits
Autor:
Agnieszka Wozniak, Tadeusz Pałko, Anita Obrycka, Henryk Skarżyński, Artur Lorens, Adam Walkowiak, Arkadiusz Wasowski
Publikováno v:
Cochlear Implants International. 11:485-488
To obtain hearing benefits after cochlear implantation it is crucial to optimally fit the system to the individual need of each patient (Wasowski et al., 2004). Great variability between patients and changes in optimal values that can be observed in
Autor:
Lukasz Bruski, Anita Obrycka, Piotr H. Skarzynski, Arkadiusz Wasowski, Artur Lorens, Adam Walkowiak
Publikováno v:
Scopus-Elsevier
The fitting procedure of the cochlear implant system introduced in the International Center of Hearing and Speech requires repeated fitting sessions that take place from three to twelve times per year, depending on the experience of cochlear implant
Autor:
Arkadiusz Wasowski, Eugen Kludt, Paul Van de Heyning, Thomas Lenarz, Christian Desloovere, Henryk Skarżyński, Ángel Ramos Macías, Caroline Vyncke, Nicolas Verhaert, Juan Carlos Falcón González, Christiane D’hondt, Jolien Desmet
Publikováno v:
Audiology and neuro-otology
The aim of this study was to investigate the efficacy of a direct acoustic cochlear implant (DACI) for speech understanding in noise in patients suffering from severe to profound mixed hearing loss (MHL) due to various etiologies compared to the preo
Publikováno v:
Cochlear implants international. 11
Autor:
Adam Walkowiak, Henryk Skarżyński, Artur Lorens, Arkadiusz Wasowski, Bozena Kostek, Anita Obrycka
Publikováno v:
Cochlear implants international. 11
(2010). Spread of Excitation (SoE) — A Non-Invasive Assessment of Cochlear Implant Electrode Placement. Cochlear Implants International: Vol. 11, Proceedings of the 9th European Symposium on Paediatric Cochlear Implantation, Warsaw, 2009, pp. 479-4
Publikováno v:
International Journal of Pediatric Otorhinolaryngology. 75:89
Publikováno v:
International Journal of Pediatric Otorhinolaryngology. 75:70
Autor:
Lukasz Bruski, Adam Walkowiak, Małgorzata Zgoda, Arkadiusz Wasowski, Piotr H. Skarzynski, Artur Lorens, Anita Obrycka, Henryk Skarżyński
Publikováno v:
International Journal of Pediatric Otorhinolaryngology. 75:93
Autor:
Henryk Skarżyński, Adam Walkowiak, Tadeusz Pałko, Anita Obrycka, Artur Lorens, Arkadiusz Wasowski
Publikováno v:
Scopus-Elsevier
Warsaw University of Technology-OmegaPSIR
11th Mediterranean Conference on Medical and Biomedical Engineering and Computing 2007 ISBN: 9783540730439
Warsaw University of Technology-OmegaPSIR
11th Mediterranean Conference on Medical and Biomedical Engineering and Computing 2007 ISBN: 9783540730439
The aim of this study was to assess the possibility of using electrically elicited stapedius muscle reflex (ESR) for estimation of most comfortable loudness level (MCL), one of the most important electrical stimulation parameter in cochlear implant s
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1b49d3db361b4a7b672f33e59dc6ba95
http://www.scopus.com/inward/record.url?eid=2-s2.0-85007038133&partnerID=MN8TOARS
http://www.scopus.com/inward/record.url?eid=2-s2.0-85007038133&partnerID=MN8TOARS