Zobrazeno 1 - 10
of 60
pro vyhledávání: '"Ansgar T. Kirk"'
Publikováno v:
Proceedings, Vol 1, Iss 4, p 443 (2017)
Gas chromatographs equipped with electron capture detectors (ECD) are widely used for the analysis of electron affine substances. Achieving limits of detection in the low pptv-range, electron capture detectors are the most sensitive detectors availab
Externí odkaz:
https://doaj.org/article/db439230f7cb4d92b4a7abed2ea43241
Autor:
Florian Schlottmann, Christoph Schaefer, Ansgar T. Kirk, Alexander Bohnhorst, Stefan Zimmermann
Publikováno v:
Journal of the American Society for Mass Spectrometry. 34:893-904
Publikováno v:
tm - Technisches Messen. 89:847-858
Low-noise current meters are usually designed using high value feedback resistors. However, a high resistance reduces the maximum measurable current at a given output voltage and the maximum bandwidth at a given parasitic capacitance. Capacitive tran
Publikováno v:
Analytical Chemistry 95 (2023), Nr. 18
Analytical Chemistry
Analytical Chemistry
In this work, we present a tandem ion mobility spectrometer (IMS) utilizing a highly efficient ion manipulator allowing to store, manipulate, and analyze ions under high electric field strengths and controlled ion-neutral reactions at ambient conditi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::998172e06d9f41f23bb84ffcf4e75cfe
https://www.repo.uni-hannover.de/handle/123456789/14247
https://www.repo.uni-hannover.de/handle/123456789/14247
Autor:
Thorsten Benter, Duygu Erdogdu, Walter Wißdorf, Ansgar T. Kirk, Maria Allers, Stefan Zimmermann, Hendrik Kersten
Publikováno v:
Journal of the American Society for Mass Spectrometry. 32:2436-2450
Ions are separated in ion mobility spectrometry (IMS) by their characteristic motion through a gas-filled drift tube with a static electric field present. Chemical dynamics, such as clustering and declustering of chemically reactive systems, and phys
Publikováno v:
Analytical chemistry. 94(28)
Efficient ionization of analyte molecules is a crucial step for the outstanding sensitivity of ion mobility spectrometers (IMS) used for trace gas detection. Here, we present a new ion source that combines the previously published extended field swit
Publikováno v:
Analytical Chemistry. 93:6062-6070
Printed circuit board (PCB) based drift tube ion mobility spectrometers enable the use of state-of-the-art production techniques to manufacture compact devices with excellent performance at minimum cost. The new PCB ion mobility spectrometer (PCB-IMS
Publikováno v:
tm - Technisches Messen. 88:262-273
While the resolving power of drift tube ion mobility spectrometers has been studied and modelled in detail over the past decades, no comparable model exists for the signal-to-noise-ratio. In this work, we develop an analytical model for the signal-to
Publikováno v:
Journal of the American Society for Mass Spectrometry. 33(6)
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) chemically ionize gaseous samples via reactant ions and separate the generated ions by their motion in a neutral gas under the influence of an electric field. Operation at reduced pressures of
Publikováno v:
Journal of the American Society for Mass Spectrometry : JASMS online 31 (2020), Nr. 7
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are usually operated at an absolute pressure of 20 mbar reaching high reduced electric field strengths of up to 125 Td for controlled reaction kinetics. This significantly increases the linear