Zobrazeno 1 - 10
of 56
pro vyhledávání: '"Anowarul Habib"'
Publikováno v:
Scientific Reports, Vol 13, Iss 1, Pp 1-12 (2023)
Abstract Scanning acoustic microscopy (SAM) is a label-free imaging technique used in biomedical imaging, non-destructive testing, and material research to visualize surface and sub-surface structures. In ultrasonic imaging, noises in images can redu
Externí odkaz:
https://doaj.org/article/7a61df39a6ab45d2abef686cdb737ecd
Autor:
Pragyan Banerjee, Shivam Milind Akarte, Prakhar Kumar, Muhammad Shamsuzzaman, Ankit Butola, Krishna Agarwal, Dilip K Prasad, Frank Melandsø, Anowarul Habib
Publikováno v:
Machine Learning: Science and Technology, Vol 5, Iss 1, p 015007 (2024)
Acoustic microscopy is a cutting-edge label-free imaging technology that allows us to see the surface and interior structure of industrial and biological materials. The acoustic image is created by focusing high-frequency acoustic waves on the object
Externí odkaz:
https://doaj.org/article/b39723971bc04d8d9f8d369eeb03b91e
Autor:
Pragyan Banerjee, Sibasish Mishra, Nitin Yadav, Krishna Agarwal, Frank Melandsø, Dilip K. Prasad, Anowarul Habib
Publikováno v:
AIP Advances, Vol 13, Iss 4, Pp 045225-045225-12 (2023)
Scanning acoustic microscopy (SAM) is a non-ionizing and label-free imaging modality used to visualize the surface and internal structures of industrial objects and biological specimens. The image of the sample under investigation is created using hi
Externí odkaz:
https://doaj.org/article/4d2551d065904ad98b0a6d20b5b53e8a
Autor:
Azeem Ahmad, Vishesh Dubey, Nikhil Jayakumar, Anowarul Habib, Ankit Butola, Mona Nystad, Ganesh Acharya, Purusotam Basnet, Dalip Singh Mehta, Balpreet Singh Ahluwalia
Publikováno v:
Scientific Reports, Vol 11, Iss 1, Pp 1-13 (2021)
Abstract High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally
Externí odkaz:
https://doaj.org/article/ee3c392fc3a545fc93bd9984698cb487
Publikováno v:
IEEE Access, Vol 9, Pp 120512-120524 (2021)
The performance of piezoelectric sensors deteriorated due to the presence of defect, delamination, and corrosion that needed to be diagnosed for the effective implementation of the structural health monitoring (SHM) framework. A novel experimental ap
Externí odkaz:
https://doaj.org/article/1150564a71c549139eea871b70008b61
Publikováno v:
Sensors, Vol 22, Iss 23, p 9161 (2022)
Lead Zirconate Titanate (PZT) is used to make ultrasound transducers, sensors, and actuators due to its large piezoelectric coefficient. Several micro-defects develop in the PZT sensor due to delamination, corrosion, huge temperature fluctuation, etc
Externí odkaz:
https://doaj.org/article/8c0dddc99c3d4616b2b866789ccc568f
Autor:
Matthias Hofmann, Ralph Pflanzer, Anowarul Habib, Amit Shelke, Jürgen Bereiter-Hahn, August Bernd, Roland Kaufmann, Robert Sader, Stefan Kippenberger
Publikováno v:
Translational Oncology, Vol 9, Iss 3, Pp 179-183 (2016)
Elevated tumor interstitial fluid pressure (TIFP) is a prominent feature of solid tumors and hampers the transmigration of therapeutic macromolecules, for example, large monoclonal antibodies, from tumor-supplying vessels into the tumor interstitium.
Externí odkaz:
https://doaj.org/article/3d7e18c00175470fa9d78c86d1880f74
Publikováno v:
Sensors, Vol 18, Iss 7, p 2017 (2018)
The main aim of the paper is damage detection at the microscale in the anisotropic piezoelectric sensors using surface acoustic waves (SAWs). A novel technique based on the single input and multiple output of Rayleigh waves is proposed to detect the
Externí odkaz:
https://doaj.org/article/40c9359d846444c1a22c247ce074b72e
Publikováno v:
Sensors, Vol 18, Iss 6, p 1908 (2018)
High-frequency unfocused polymer array transducers are developed using an adhesive-free layer-by-layer assembly method. The current paper focuses on experimental and numerical methods for measuring the acoustic performance of these types of array tra
Externí odkaz:
https://doaj.org/article/4bf7ae85620948b197f8281b9dd5184a
Publikováno v:
Mechanical Systems and Signal Processing. 197:110360