Zobrazeno 1 - 10
of 78
pro vyhledávání: '"Annette Kettler"'
Publikováno v:
Der Orthopäde. 39:565-572
Interspinous spacers are commonly used to treat lumbar spinal stenosis or facet joint arthritis. The aims of implanting interspinous devices are to unload the facet joints, restore foraminal height, and provide stability especially in extension but s
Autor:
Lutz Claes, K. Haeussler, Frank Heuer, Annette Kettler, C. Mack, Hans-Joachim Wilke, Joerg Drumm
Publikováno v:
Clinical Biomechanics
Interspinous spacers are mainly used to treat lumbar spinal stenosis and facet arthrosis. Biomechanically, they stabilise in extension but do not compensate instability in axial rotation and lateral bending. It would therefore be desirable to have an
Autor:
Keita Ito, Hans-Joachim Wilke, Christopher B. Little, Ian A. F. Stokes, Koichi Masuda, James Melrose, Annette Kettler, Mauro Alini, James Robert Ralphs, Stephen M. Eisenstein
Publikováno v:
European Spine Journal, 17(1), 2-19. Springer
Intervertebral disc (IVD) degeneration is an often investigated pathophysiological condition because of its implication in causing low back pain. As human material for such studies is difficult to obtain because of ethical and government regulatory r
Publikováno v:
SAS Journal
Background One of the greatest challenges in the development of a nucleus prosthesis is to minimize the risk of implant expulsion. At the same time, the physiological flexibility, compressive behavior, and height of the disc should be restored. In th
Autor:
L. Issler, Karin Werner, Lutz Claes, M. Mahalingam, Annette Kettler, Thomas Niemeyer, Hans-Joachim Wilke, U. Merk
Publikováno v:
Clinical Biomechanics
Background Cages are commonly used to assist lumbar interbody fusion. They are implanted from various approaches. In many cases internal fixators are added to provide sufficient stability. However, how the rods of these fixators are loaded and whethe
Autor:
Hendrik Schmidt, Antonius Rohlmann, Ulrich Simon, Lutz Claes, Frank Heuer, Annette Kettler, Hans-Joachim Wilke
Publikováno v:
Clinical Biomechanics
Background Major deficits of many finite element models of the lumbar spine are the oversimplification, assumed constellation of the material properties or the insufficiently performed calibration using experimental in vitro data. The aim of this stu
Publikováno v:
Journal of Biomechanics
The aim of the present in vitro study was to investigate the effect of the crash pulse shape on the peak loading and the injury tolerance levels of the human neck. In a custom-made acceleration apparatus 12 human cadaveric cervical spine specimens, e
Autor:
Hans-Joachim Wilke, Friederike Rohlmann, Cornelia Neidlinger-Wilke, Karin Werner, Lutz Claes, Annette Kettler
Publikováno v:
European Spine Journal
Many different radiographic grading systems for disc degeneration are described in literature. However, only a few of them are tested for interobserver agreement and none for validity. Furthermore, most of them are based on a subjective terminology.
Publikováno v:
Spine
Study Design. An in vitro biomechanical flexibility test on different lumbar interbody fusion cages using monosegmental lumbar spine specimens. Objective. To investigate the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage c
Autor:
Markus Schultheiss, Lothar Kinzl, Erich Hartwig, Martin Elbel, Michael Kramer, Annette Kettler
Publikováno v:
Der Unfallchirurg. 107:1135-1141
Die Differenzierung zwischen degenerativen Krankheitsbildern der Halswirbelsaule (HWS) und unfallbedingten Beschwerden erfordert unfallanalytische Betrachtungen. Probandenversuche ergeben Daten im Niedrigenergiebereich, unfallanalytische Untersuchung