Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Anna Kin Yin CHAN"'
Autor:
Mark Tsz Kin TAM, Anna Kin Yin CHAN, Alex Chi Kin Au, Lily CHEUNG, Gary Chin Pang Chan, Joseph Yat Sun Chan
Publikováno v:
Journal of the Hong Kong College of Cardiology. 29:43-52
Autor:
Chak-Yu, So, Yat-Yin, Lam, Gary Shing-Him, Cheung, Kevin Ka-Ho, Kam, Anna Kin-Yin, Chan, Alex Pui-Wai, Lee, Bryan P, Yan
Publikováno v:
The Journal of invasive cardiology. 31(2)
Although reported failure rates of the Watchman device are low, the ballshaped device is not suitable for shallow and multilobed left atrial appendages (LAAs). The LAmbre device is available in two configurations - standard (cover 4-6 mm larger in di
Autor:
Chak-Yu So, Gary Shing-Him Cheung, Wai-Kin Chi, Bryan P. Yan, Kevin Ka-Ho Kam, Anna Kin-Yin Chan
Publikováno v:
Circulation: Cardiovascular Imaging. 11
Publikováno v:
Journal of the American College of Cardiology. 72(4)
We commend Fauchier et al. [(1)][1] for their important work that stirred up debates on the future development of left atrial appendage occlusion (LAAO). Their study reported a 7.2% device-related thrombus (DRT) rate, which was higher than most previ
Autor:
Yat-Yin Lam, Jai-Wun Park, Bryan P. Yan, Gary Shing-Him Cheung, Christy K.Y. Chan, Boris Schmidt, Shaojie Chen, Chak-Yu So, Anna Kin-Yin Chan
Publikováno v:
JACC: Cardiovascular Interventions. 11:1113-1114
Left atrial appendage occlusion (LAAO) is predominantly performed under general anesthesia, guided by transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE). The LAmbre (Lifetech Science, Shenzhen, China) is a novel LAAO device
Autor:
Ka-Wai Kwok, Marco Chow, Anna Kin-Yin Chan, Dee Dee Wang, Gary Shing-Him Cheung, Kevin Ka-Ho Kam, Martin C. W. Leong, Zhiqing Qiao, Alex Pui-Wai Lee, Ben He, Yat-Yin Lam, Yiting Fan, Gary Tse, Kent Chak-Yu So, Fan Yang
Publikováno v:
Journal of the American Society of Echocardiography. 32:708-719.e1
Left atrial appendage (LAA) occlusion is an alternative to anticoagulation for stroke prevention in patients with atrial fibrillation. Accurate device sizing is crucial for optimal outcome. Patient-specific LAA models can be created using three-dimen
Three-Dimensional Printing for Planning Occlusion Procedure for a Double-Lobed Left Atrial Appendage
Autor:
Yiting Fan, Ka-Wai Kwok, Anna Kin-Yin Chan, Alex Pui-Wai Lee, Yiqun Zhang, Gary Shing-Him Cheung
Publikováno v:
Circulation: Cardiovascular Interventions. 9
A 78-year-old woman with atrial fibrillation and contraindication to oral anticoagulation because of high bleeding risk was referred for catheter-based left atrial appendage (LAA) occlusion. Preprocedural transesophageal echocardiography (TEE) using
Autor:
Alex Pui-Wai Lee, Ka-Wai Kwok, Anna Kin-Yin Chan, Gary Shing-Him Cheung, Yiting Fan, Kent Chak-Yu So, Louis Kwan Yik Sze
Publikováno v:
JACC: Cardiovascular Interventions. 10:e97-e98
A 56-year-old woman presented with dyspnea 6 months after percutaneous closure of atrial septal defect with a Cocoon Septal Occluder. Transesophageal echocardiography revealed partial device prolapse and recurrent left-to-right interatrial shunt thro
Autor:
Jen-Li Looi, Chin-Pang Chan, Anna Kin-Yin Chan, Joseph Y.S. Chan, Cheuk-Man Yu, Alex Pui-Wai Lee, Ka-Tak Wong, Mable Tong
Publikováno v:
Journal of the American College of Cardiology. 62(3)
[Figure][1] [![Graphic][3] ][3] A 52-year-old woman became hypotensive during radiofrequency ablation for paroxysmal atrial fibrillation. She received heparin 5,000 IU after transseptal puncture, and continued as an infusion to maintain an activated
Autor:
Pui-Wai Lee, Cheuk-Man Yu, Eugene B. Wu, Qing Zhang, Gabriel W.K. Yip, Shun-Ling Kong, Anna Kin-Yin Chan, Joseph Y.S. Chan, Yat-Yin Lam, Leo C.C. Kum, Jeffrey W.H. Fung
Publikováno v:
International journal of cardiology. 125(1)
Angiotensin-converting enzyme inhibitor (ACEI) is beneficial in patients with congestive heart failure (CHF). Some, but not all, angiotensin receptor blocker (ARB) was demonstrated to be effective as "add-on" therapy. We investigated whether irbesart