Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Angioplasty device"'
Autor:
Simon J. Mountford, John S. Forsythe, Patrick J Mornane, Philip E. Thompson, Andrea J. Robinson, Melissa Byrne, Gopal R Sama, Helmut Thissen, Andrew Edwin Rodda, David M. Kaye, Anthony E. Dear, Hong Bin Liu, Paul Pasic
Publikováno v:
Cardiovascular Engineering and Technology. 12:466-473
Paclitaxel (PTX)-coated drug eluting balloon catheters (DEBc) used in the management of neointimal hyperplasia (NIH) have been associated with safety concerns. Alternative coating agents and targeted delivery systems may improve safety and DEBc effic
Publikováno v:
SpringerBriefs in Materials ISBN: 9783030424428
It is estimated that 600,000 to 1 million cardiac catheterizations (CC) are performed annually in the United States. This figure exceeds the number of coronary artery bypass graft procedures (CABG) performed on an annual basis, and is expected to gro
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::32a0912a0d74abed6c565f1dfad136a9
https://doi.org/10.1007/978-3-030-42443-5_6
https://doi.org/10.1007/978-3-030-42443-5_6
AngioSculpt®scoring balloon catheter: an atherotomy device for coronary and peripheral interventions
Publikováno v:
Interventional Cardiology. 2:469-478
This article reviews the AngioSculpt® (AngioScore, CA, USA) scoring balloon catheter, one of the newest atherotomy-based systems used in the treatment of both coronary and peripheral vascular disease. We examine the clinically relevant aspects of th
Autor:
Mohan Honnayya Nayak, Rangraj Ramalingam, Shivanand Patil, Cholenahally Nanjappa Manjunath, Jayashree Kharge
Publikováno v:
Journal of Clinical and Diagnostic Research, Vol 9, Iss 10, Pp OD01-OD03 (2015)
Breakage of angioplasty device in coronary artery can cause panic in the catheterization laboratory. These broken fragments may serve as a nidus for thrombus formation; hence, removal of these fragments becomes mandatory. Since the incidence of guide
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3ed3a278284707d9679bd8973d2329b2
https://europepmc.org/articles/PMC4625276/
https://europepmc.org/articles/PMC4625276/
Drilling through impacted ureteral stones: use of the atherectomy rotablator device for urolithiasis
Autor:
David A. Lifshitz, Kevin C. Zorn, Glenn S. Gerber, Sergey Shikanov, Naeem Bhojani, Aria Razmaria, Arieh L. Shalhav, Ofer N. Gofrit
Publikováno v:
Journal of endourology. 24(7)
The Rotablator is an angioplasty device that is passed over a wire. It uses a high-speed rotational "burr" (2 mm in diameter) that is coated with microscopic diamond particles and cooled by saline. It rotates at high speed (approximately 200,000 rpm)
Autor:
L A Rozenszajn, Charles C. Marboe, D David, U Rosenschein, J F Watkins, Paul J. Cannon, J S Weinstein, L Kraus, Eric A. Rose
Publikováno v:
Circulation. 83:1976-1986
BACKGROUND Ultrasonic angioplasty was recently shown to ablate thrombi and atherosclerotic plaques in vitro and to recanalize occluded arteries in experimental animal models. The goal of the present study was to examine the clinical feasibility of ul
Publikováno v:
Journal of the American College of Cardiology. 60(17):B128-B129
Autor:
Anne H. Coulter
Publikováno v:
Journal of Clinical Laser Medicine & Surgery. 9:405-407
Publikováno v:
Conference Papers
Ultrasonic angioplasty involves the use of ultrasonic vibrations delivered to the distal-tip of small diameter wire waveguides and is an emerging technology the may have potential use in the treatment of complicated atherosclerotic plaques during car
Kniha