Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Andrzej Szromba"'
Autor:
Andrzej Szromba
Publikováno v:
Energies, Vol 17, Iss 20, p 5098 (2024)
Determining the current reference for a shunt active power filter (SAPF) can be carried out in many ways. Once the reference is determined, it can be shaped by SAPF switches with the use of pulse width modulation (PWM)/hysteresis control techniques.
Externí odkaz:
https://doaj.org/article/67c440c9d7a04532a9e480bb1dd28c3f
Autor:
Andrzej Szromba
Publikováno v:
Energies, Vol 16, Iss 10, p 4080 (2023)
Calculation of the reference waveform for the compensating current generated by the shunt active power filter (ShAPF) can be carried out using various methods. In this article, this calculation is performed indirectly on the basis of tracking and pro
Externí odkaz:
https://doaj.org/article/2d32396cd7c347379cb4846e565962c4
Autor:
Andrzej Szromba
Publikováno v:
Energies, Vol 14, Iss 19, p 6031 (2021)
This paper presents a simple yet efficient control method for active power filters that can be used to improve power quality. Applying this method can open the way towards limiting the hardware and computational expenditure, which are needed for cont
Externí odkaz:
https://doaj.org/article/13e8e0b1df4747d29cc0b57894eea931
Autor:
Andrzej Szromba
Publikováno v:
Energies, Vol 13, Iss 23, p 6298 (2020)
This paper proposes a new control method for a Unified Power Quality Conditioner (UPQC). This method is based on the load equivalent conductance approach, originally proposed by Fryze. It can be useful not only for compensation for nonactive current
Externí odkaz:
https://doaj.org/article/b75c4f107abc41488661f2c52577a7fa
Autor:
Andrzej Szromba
Publikováno v:
PRZEGLĄD ELEKTROTECHNICZNY. 1:35-38
Autor:
Andrzej Szromba
Publikováno v:
COMPEL - The international journal for computation and mathematics in electrical and electronic engineering. 36:702-715
Purpose The purpose of this study is to find a control method for three-phase four-wire shunt active power filters, which uses a load-equivalent conductance for obtaining a reference signal for compensating non-active current. Design/methodology/appr
Autor:
Bartłomiej Sysło, Andrzej Szromba
Publikováno v:
2019 15th Selected Issues of Electrical Engineering and Electronics (WZEE).
In the paper a new method of controlling of operation of series-parallel active filters UPQC has been presented. The idea of load equivalent conductance according to S. Fryze is exploited in the paper. The presented method allows conventional compens
Autor:
Andrzej Szromba
Publikováno v:
Archives of Electrical Engineering. 64:259-275
This paper presents a load equivalent conductance based control method for a shunt active power filter. The principle of energy balance in the circuit, which means between supplying source - active filter - load, is used to obtain the control formula
Autor:
Wojciech Mysiński, Andrzej Szromba
Publikováno v:
2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe).
A universal control method for shunt active power filters based on the notion of load equivalent conductance is presented. The considered technique is often referred to as the closed-loop indirect control, or the global compensation method. This tech
Autor:
Andrzej Szromba
Publikováno v:
Archives of Electrical Engineering. 62:55-75
The considered shunt active power filter can be controlled not only to compensate non-active current in the supply source, but additionally to optimize energy flow between the source and the load. In such a case the filter shapes the source current t