Autor:
Andrew D. Wiles, Terry M. Peters
Publikováno v:
IEEE Transactions on Medical Imaging. 29:879-894
In recent years, magnetic tracking systems, whose fundamental unit of measurement is a 5D transformation (three translational and two rotational degrees-of-freedom), have become much more popular. Two 5D sensors can be combined to obtain a 6D transfo
Autor:
Gerard M. Guiraudon, Daniel Bainbridge, Andrew D. Wiles, Douglas L. Jones, John Moore, Chris Wedlake, Cristian A. Linte, Terry M. Peters
Publikováno v:
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 4:20-26
Objective Optimal atrial septal defect (ASD) closure should combine off-pump techniques with the effectiveness and versatility of open-heart techniques. We report our experience with off-pump ASD closure using the Universal Cardiac Introducer (UCI) i
Publikováno v:
IEEE Transactions on Medical Imaging. 27:378-390
Error models associated with point-based medical image registration problems were first introduced in the late 1990s. The concepts of fiducial localizer error, fiducial registration error, and target registration error are commonly used in the litera
Publikováno v:
Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention. 12(Pt 1)
In image-guided interventions, anatomical models of organs are often generated from pre-operative images and further employed in planning and guiding therapeutic procedures. However, the accuracy of these models, along with their registration to the
Autor:
Terry M. Peters, Andrew D. Wiles, John Moore, Chris Wedlake, Maxim Rachinsky, Daniel Bainbridge
Publikováno v:
Medical Imaging: Image-Guided Procedures
Peripheral nerve block treatments are ubiquitous in hospitals and pain clinics worldwide. State of the art techniques use ultrasound (US) guidance and/or electrical stimulation to verify needle tip location. However, problems such as needle-US beam a
Autor:
D. Bainbridge, Terry M. Peters, Chris Wedlake, Ana Luisa Trejos, John Moore, Rajni V. Patel, Andrew D. Wiles, Bob Kiaii
Publikováno v:
Medical Imaging: Image-Guided Procedures
Trans-esophageal echocardiography (TEE) is a standard component of patient monitoring during most cardiac surgeries. In recent years magnetic tracking systems (MTS) have become sufficiently robust to function effectively in appropriately structured o
Publikováno v:
Medical Image Computing and Computer-Assisted Intervention – MICCAI 2010 ISBN: 9783642157103
MICCAI (3)
MICCAI (3)
Image-guided surgery systems have a wide range of applications where the level of accuracy required for each application varies from millimeters to low sub-millimeter range. In systems that use optical tracking, it is typical to use point-based regis
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d0e2bec25e0c8cf7dfd386ec241cec96
https://doi.org/10.1007/978-3-642-15711-0_73
https://doi.org/10.1007/978-3-642-15711-0_73
Autor:
Terry M. Peters, Andrew D. Wiles
Publikováno v:
IEEE transactions on medical imaging. 28(9)
Target registration error (TRE) has become a widely accepted error metric in point-based registration since the error metric was introduced in the 1990s. It is particularly prominent in image-guided surgery (IGS) applications where point-based regist
Autor:
Chris Wedlake, Terry M. Peters, David G. Gobbi, Danielle F. Pace, Andrew D. Wiles, John Moore
Publikováno v:
Medical Imaging: Image-Guided Procedures
Ultrasound is garnering significant interest as an imaging modality for surgical guidance, due to its affordability, real-time temporal resolution and ease of integration into the operating room. Minimally-invasive intracardiac surgery performed on t
Publikováno v:
Medical Imaging: Image-Guided Procedures
Catheter-driven cardiac interventions have emerged in response to the need of reducing invasiveness associated with the traditional cut-and-sew techniques. Catheter manipulation is traditionally performed under real-time fluoroscopy imaging, resultin