Zobrazeno 1 - 10
of 114
pro vyhledávání: '"Andrew A. Gooley"'
Autor:
Ibraam E. Mikhail, Masoomeh Tehranirokh, Andrew A. Gooley, Rosanne M. Guijt, Michael C. Breadmore
Publikováno v:
Angewandte Chemie. 132:23362-23368
Autor:
Paul R. Haddad, Lewellwyn J. Coates, Brett Paull, Steven M. Guinness, Andrew A. Gooley, Hans-Jurgen Wirth, Frank Riley, Shing C. Lam, S. Sonja Sekulic, Mohamed Hemida, Angel R. Diaz
Publikováno v:
Journal of chromatography. A. 1656
Liquid chromatography (LC) has broad applicability in the pharmaceutical industry, from the early stages of drug discovery to reaction monitoring and process control. However, small footprint, truly portable LC systems have not yet been demonstrated
In-Syringe Electrokinetic Ampholytes Focusing Coupled with Electrospray Ionization Mass Spectrometry
Autor:
Ibraam E Mikhail, Masoomeh Tehranirokh, Andrew A. Gooley, Michael C. Breadmore, Rosanne M. Guijt
Publikováno v:
Analytical Chemistry. 91:8259-8266
A 25 μL analytical glass syringe has been used for isoelectric focusing (IEF) utilizing the stainless-steel needle and plunger as electrodes. The generation of protons and hydroxyl ions at the electrodes facilitated a neutralization reaction boundar
Autor:
Rosanne M. Guijt, Masoomeh Tehranirokh, Michael C. Breadmore, Andrew A. Gooley, Ibraam E Mikhail
Publikováno v:
Journal of chromatography. A. 1646
Stand-alone electrospray ionization mass spectrometry (ESI-MS) has been advancing through enhancements in throughput, selectivity and sensitivity of mass spectrometers. Unlike traditional MS techniques which usually require extensive offline sample p
Autor:
Brett Paull, Mirek Macka, Shing-Chung Lam, Lewellwyn J. Coates, Mohamed Hemida, Andrew A. Gooley, Hans-Juergen Wirth, Vipul Gupta, Paul R. Haddad
Publikováno v:
Analytical chemistry. 92(20)
A new miniature deep UV absorbance detector has been developed using low-cost and high-performance LEDs, which can be operated in both scanning (230 to 300 nm) and individual wavelength (240, 255, and 275 nm) detection modes. The detector is mostly c
Publikováno v:
Analytical and Bioanalytical Chemistry. 410:3315-3323
An accurate and precise 3 μL blood collection and dispensing system is presented for the preparation of dried blood spot (DBS) samples. Using end-to-end glass capillaries in conjugation with pre-punched DBS pads, a blood micro collection system was
Publikováno v:
Langmuir. 33:14220-14225
Capillary action is one mechanism microfluidics uses to draw liquid autonomously in a substrate without the need of external energy. This behavior can be exploited to collect accurate volumes of liquids such as blood in narrow columns known as capill
Autor:
Vipul Gupta, Shing-Chung Lam, Andrew A. Gooley, Hans-Jurgen Wirth, Lewellwyn J. Coates, Brett Paull, Paul R. Haddad
Publikováno v:
Journal of Chromatography A. 1631:461540
A new miniaturised capillary flow-through deep-UV absorbance detector has been developed using a microscale surface mounted device- type light-emitting diode (LED) (Crystal IS OPTAN 3535-series), emitting at 235 nm and with a half-height band width o
Autor:
Brett Paull, Robert A. Shellie, Trevor W. Lewis, Andrew A. Gooley, Pavel N. Nesterenko, Chowdhury Kamrul Hasan, Hans-Jurgen Wirth
Publikováno v:
Journal of Chromatography A. 1613:460669
The development and application of non-porous and porous sorptive rods, comprised of polydimethylsiloxane–microdiamond (PDMS-MD) composites, is reported. The PDMS-MD composites were made porous using inorganic salt (NaCl and NaHCO3) particles as di
Publikováno v:
Journal of Chromatography A. 1410:9-18
While polymer monoliths are widely described for solid phase extraction (SPE), appropriate characterization is rarely provided to unravel the links between physical characteristics and observed advantages and disadvantages. Two known approaches to fa