Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Andreas Steurer"'
Publikováno v:
Radiation Protection Dosimetry. 199:754-758
The applicability of the ISO slab phantom as calibration phantom for the new ICRU report 95 quantity personal dose should be legitimated by simulations and measurements of backscatter factors on the ISO slab phantom and, comparatively, on a human-lik
Publikováno v:
Journal of radiological protection : official journal of the Society for Radiological Protection. 42(2)
In this article, the proposal of the International Commission on Radiation Units and Measurements/International Commission on Radiological Protection (ICRU/ICRP), that the ISO slab phantom should continue to be used as a calibration phantom for the n
Autor:
Jacco de Pooter, Andreas Steurer, Liviu-Cristian Mihailescu, Christian Kottler, Cristina García Mulas, F. Delaunay
Publikováno v:
Metrologia. 57:06013
The air kerma and absorbed dose to water standards for 60Co radiotherapy beams of 6 EURAMET NMIs were compared by circulating 2 transfer standards. The schedule for the measurements lasted from March 2013 to February 2015. The participants determined
Publikováno v:
Metrologia. 55:06010
A bilateral comparison of standards for absorbed dose to water and air kerma of the Bundesamt für Eich- und Vermessungswesen (BEV), Austria, and of the Vinca Institute of Nuclear Sciences (VINS), Serbia, has been carried out. It was performed for ai
Autor:
Andreas Steurer, F. Gabris, F.J. Maringer, Wilhelm Tiefenböck, Andreas Baumgartner, Gerhard Stucki, Ralf-Peter Kapsch
Publikováno v:
Radiation protection dosimetry. 145(1)
The graphite calorimeter of the Federal Office of Metrology and Surveying (BEV-Bundesamt fur Eich- und Vermessungswesen) was established in the 1980s as the primary standard for the absorbed dose to water for (60)Co gamma ray beams. To maintain the p
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 67(11)
Photon energy spectra of Varian Clinac 2100C and 2300C/D treatment heads were calculated with PENELOPE-2006, using simplified Monte Carlo models. These spectra constitute the basis of beam models used for the calculation of correction factors require
Publikováno v:
Metrologia. 47:06006-06006
Publikováno v:
Metrologia. 47:06017-06017
A comparison of the standards for absorbed dose to water of the Bundesamt f?r Eich- und Vermessungswesen (BEV), Austria, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2009
Publikováno v:
Metrologia. 47:06007-06007
A direct comparison of the standards for air kerma of the Bundesamt fur Eich- und Vermessungswesen (BEV), Austria, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in March 2009. The
Publikováno v:
Radiation Protection Dosimetry; Jun2023, Vol. 199 Issue 8/9, p754-758, 5p