Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Andreas Katerkamp"'
Autor:
Andreas Katerkamp, Monica Florescu
Publikováno v:
Sensors and Actuators B: Chemical. 97:39-44
A method for detection of viable cells utilises a sensor based on the optical measurement of oxygen consuming by cells. Changes in the oxygen level were measured via quenching of the fluorescence of an oxygen-sensitive fluorophor (Ru(dpp) 3Cl2). The
Publikováno v:
Biosensors and Bioelectronics. 13:1141-1147
In the present paper surface studies for the development of a direct optical immunosensor for fast diagnosis of a myocardial infarction are presented. A fatty acid binding protein was detected by monoclonal antibodies. The applied measuring system wa
Publikováno v:
Sensors and Actuators B: Chemical. 51:249-255
An optical immunosensor system consisting of a disposable low-cost sensor chip including a fluidic system and a base unit for optical readout was developed. Near infrared (NIR)-fluorescence markers (Cy5) were excited by an evanescent wave generated o
Publikováno v:
Colloids and Surfaces B: Biointerfaces. 10:273-279
In the present study, the application of several methods for the determination of an immobilized protein are presented and the results discussed. Streptavidin was bound covalently on gold and silica surfaces. A radio assay was used as a reference met
Autor:
Friedrich Spener, Erk Gedig, Andreas Katerkamp, Manfred Lacher, Wolfgang Ehrfeld, H. Freimuth, Karl Cammann, Franz Brosinger
Publikováno v:
Sensors and Actuators B: Chemical. 44:350-355
An integrated optical Mach–Zehnder interferometer (IO-MZI) on silicon was specially designed and tested for application as an affinity sensor. In order to obtain the necessary sensitivity, an optimisation of the refractive index and the thickness o
Publikováno v:
Sensors and Actuators B: Chemical. 32:149-155
The human heart-type fatty acid binding protein (H-FABP) can be used as an early heart infarction marker in clinical diagnostics because its concentration in blood plasma increases about 1.5 to 3 hours after the onset of an acute myocardial infarctio
Publikováno v:
Mikrochimica Acta. 119:63-72
In this paper the theoretical base and experimental results of a new class of fiber optical supported surface plasmon resonance spectroscopy (SPRS) transducer is given. Surface plasmons were excited by polychromatic light, and the resonant excitation
Autor:
Cornelia Middendorf, Thomas Rump, Andreas Katerkamp, Karl Cammann, Monika Wortberg, Jörg Krause
Publikováno v:
Analytica Chimica Acta. 289:177-186
An immunochemical flow-injection system for the determination of triazine herbicides based on principles of immunoaffinity chromatography was developed. Triazine herbicide derivatives immobilized on oxirane acrylic beads serve as the affinity column.
Autor:
Maria Pellmann, Andreas Katerkamp, Jörg Reinbold, Karl Cammann, Matthias Niggemann, Peter Bolsmann
Publikováno v:
Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.
A miniaturized fibre optical sensor based on surface plasmon resonance spectroscopy is investigated in view of the detection of organic solvent vapours, particularly tetrachloroethene. Surface plasmons are excited on a silver coated multimode fibre b
Publikováno v:
Fresenius' journal of analytical chemistry. 371(2)
An optical sensor system based on evanescent field excitation of fluorophore-labeled DNA-targets specifically binding to immobilized DNA probes has been developed, thus enabling for real-time analysis of hybridization events. Oligonucleotide probes a