Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Andreas Genner"'
Publikováno v:
Sensors, Vol 20, Iss 7, p 1850 (2020)
A quantum cascade laser-based sensor for ambient air monitoring is presented and five gases, affecting the air quality, can be quantified. The light sources are selected to measure CO, NO, NO2, N2O and SO2. The footprint of the measurement setup is d
Externí odkaz:
https://doaj.org/article/b1fe2b692cb743dd819beadddf1e6398
Publikováno v:
Sensors and Actuators B: Chemical. 242:9-14
The design and application of a versatile, tunable filtometer based on a Fabry-Perot (FP) tunable filter – detector, covering the spectral range from 1250 to 1850 cm−1 at a spectral resolution of approximately 30 cm−1, is presented. The tunable
Publikováno v:
Quantum Sensing and Nano Electronics and Photonics XVI.
Commercial gas sensors based on quantum cascade laser (QCL) spectroscopy usually rely on a single measurement technique, such as the direct absorption approach, the photoacoustic method, or measuring the dispersion. While each method has its advantag
Publikováno v:
Scopus-Elsevier
Autor:
Harald Moser, Johannes Ofner, Bernhard Lendl, Andreas Genner, Josef Schreiber, Christoph Gasser
Publikováno v:
Analytical and Bioanalytical Chemistry
On-line monitoring of key chemicals in an industrial production plant ensures economic operation, guarantees the desired product quality, and provides additional in-depth information on the involved chemical processes. For that purpose, rapid, rugged
Publikováno v:
Conference on Lasers and Electro-Optics.
Hydrogen sulfide (H2S), methyl mercaptan (CH3SH) and carbonyl sulfide (COS) gas detection based on second harmonic wavelength modulation spectroscopy (2f-WMS) using three modulation frequency multiplexed continuous wave quantum cascade lasers (cw QCL
Publikováno v:
Optics Express. 27:15575
This article presents the first implementation and the experimental characterization of a thermal infrared wavelength modulation laser heterodyne radiometer (WM-LHR) based on an external cavity quantum cascade laser. This novel WM-LHR system has demo
Autor:
Harald, Moser, Andreas, Genner, Johannes, Ofner, C, Schwarzer, Gottfried, Strasser, Bernhard, Lendl
Publikováno v:
Optics express. 24(6)
The present work reports on the first application of a ring-cavity-surface-emitting quantum-cascade laser (RCSE-QCL) for sensitive gas measurements. RCSE-QCLs are promising candidates for optical gas-sensing due to their single-mode, mode-hop-free an
Publikováno v:
Applied Physics B. 110:233-239
This work reports on a compact sensor for fast and reagent-free point-of-care determination of glucose, lactate and triglycerides in blood serum based on a tunable (1030–1230 cm−1) external-cavity quantum cascade laser (EC-QCL). For simple and ro
Publikováno v:
Procedia Engineering. 5:1001-1004
A novel approach for a physical chemosensor for liquids based on mid-infrared (mid-IR) laser spectroscopy is presented. Mid-infrared sensor systems access chemical information directly through measuring vibrational spectra of the samples under invest