Zobrazeno 1 - 10
of 400
pro vyhledávání: '"Andreas, Büchner"'
Autor:
Jenny Stritzel, Amir Hossein Ebrahimzadeh, Andreas Büchner, Heinrich Lanfermann, Michael Marschollek, Dominik Wolff
Publikováno v:
Scientific Reports, Vol 14, Iss 1, Pp 1-13 (2024)
Abstract Cochlear implants can provide an advanced treatment option to restore hearing. In standard pre-implant procedures, many factors are already considered, but it seems that not all underlying factors have been identified yet. One reason is the
Externí odkaz:
https://doaj.org/article/0428321015f84bd1921c3458e019ec86
Publikováno v:
Scientific Reports, Vol 13, Iss 1, Pp 1-17 (2023)
Abstract Vibrotactile stimulation is believed to enhance auditory speech perception, offering potential benefits for cochlear implant (CI) users who may utilize compensatory sensory strategies. Our study advances previous research by directly compari
Externí odkaz:
https://doaj.org/article/8ce4d548ca734627a3fca78414257985
Publikováno v:
Applied Sciences, Vol 13, Iss 14, p 8411 (2023)
Smartphones are increasingly being used to enable patients to play an active role in managing their own health through applications, also called apps. The latest generation of sound processors for cochlear implants offer Bluetooth connectivity that m
Externí odkaz:
https://doaj.org/article/5413fc6a0bfa4e32b09976974b37709d
Autor:
Verena Scheper, Melanie Schmidtheisler, Florian Lasch, Heiko von der Leyen, Armin Koch, Jana Schwieger, Andreas Büchner, Anke Lesinski-Schiedat, Thomas Lenarz
Publikováno v:
Trials, Vol 21, Iss 1, Pp 1-14 (2020)
Abstract Background The standard therapy for patients suffering from sensorineural hearing loss is cochlear implantation. The insertion of the electrode array into the cochlea, with potential mechanical trauma and the presence of this foreign body in
Externí odkaz:
https://doaj.org/article/0e03aba5689f4ab3943e9853368e523a
Publikováno v:
PLoS ONE, Vol 16, Iss 4, p e0249535 (2021)
The measurement of the electrically evoked compound action potential (ECAP) in cochlear implant (CI) patients is widely used to provide evidence of a functioning electrode-nerve interface, to confirm proper location of the electrode array and to prog
Externí odkaz:
https://doaj.org/article/33208df04aed4b77a15e35309d7d90cc
Publikováno v:
PLoS ONE, Vol 16, Iss 12, p e0261295 (2021)
ObjectivesThe relationship between electrode-nerve interface (ENI) estimates and inter-subject differences in speech performance with sequential and simultaneous channel stimulation in adult cochlear implant listeners were explored. We investigated t
Externí odkaz:
https://doaj.org/article/498226c8e5c448febfe73e62f82da549
Autor:
Rolf Benedikt Salcher, Melanie Schmidtheisler, Andreas Büchner, Thomas Giere, Denise Zimmermann, Susan Busch, Max Eike Timm, Hannes Maier, Thomas Lenarz
Publikováno v:
Otolaryngology Case Reports, Vol 16, Iss , Pp 100182- (2020)
Background: Previous studies in the field of cochlear implantation have proven that the use of electro-acoustic stimulation systems in patients with low frequency residual hearing results in improved speech perception scores compared to electric only
Externí odkaz:
https://doaj.org/article/9ff7006fa57240b6904c2fe05f302860
Autor:
Mariella Kessler, Irina Schierholz, Martin Mamach, Florian Wilke, Anja Hahne, Andreas Büchner, Lilli Geworski, Frank M. Bengel, Pascale Sandmann, Georg Berding
Publikováno v:
Frontiers in Neuroscience, Vol 14 (2020)
Cochlear implantation constitutes a successful therapy of inner ear deafness, with the majority of patients showing good outcomes. There is, however, still some unexplained variability in outcomes with a number of cochlear-implant (CI) users, showing
Externí odkaz:
https://doaj.org/article/9950c30871144468963353e79d02592a
Autor:
Lutz Gärtner, Timo Bräcker, Mathias Kals, Richard T. Penninger, Mareike Billinger-Finke, Thomas Lenarz, Andreas Büchner
Publikováno v:
Life, Vol 12, Iss 2, p 269 (2022)
This study assessed the safety and performance of ARTFit, a new tool embedded in MAESTRO, the cochlear implant (CI) system software by MED-EL GmbH (Innsbruck, Austria). ARTFit automatically measures thresholds of the electrically evoked compound acti
Externí odkaz:
https://doaj.org/article/aa0a0abc672b496abd046da49951ae8d
Publikováno v:
BioMedical Engineering OnLine, Vol 17, Iss 1, Pp 1-13 (2018)
Abstract Background In cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech
Externí odkaz:
https://doaj.org/article/1e3d90e2a3e34ef88133874bfa97fb70