Zobrazeno 1 - 6
of 6
pro vyhledávání: '"Andrés A. Sánchez-Escalona"'
Publikováno v:
Revista Centro Azúcar, Vol 47, Iss 4, Pp 32-44 (2020)
Introducción: El proyecto actual de centrales eléctricas (CE) de biomasa en la industria azucarera de Cuba, tiene como limitante el acceso al agua requerida por las instalaciones de condensación. En la actualidad, el uso de condensadores secos es
Externí odkaz:
https://doaj.org/article/7ab8b18736d440abaf4e0cc77fd72e0d
Autor:
Andrés Adrian Sánchez-Escalona, Ever Góngora-Leyva, Carlos Zalazar-Oliva, Edel Álvarez-Hernández
Publikováno v:
Minería y Geología, Vol 33, Iss 3, Pp 326-340 (2017)
The sulphide acid coolers are tube and shell jacketed heat exchangers designed to cool down the produced gas from 416,15 K to 310,15 K in addition to separate the sulphur carried over by the outlet gas from the reactor tower. The investigation was ca
Externí odkaz:
https://doaj.org/article/374f7872cfd642e5b9b0b673901b3541
Publikováno v:
Centro Azúcar, Vol 47, Iss 4, Pp 32-44 (2020)
Introduction: The current biomass power plant (CE) project in Cuban sugar industry is limited by water access required by condensation facilities. At present, the use of dry condensers is the most widespread solution worldwide to reduce high rates of
Autor:
Carlos Zalazar-Oliva, Ever Góngora-Leyva, Yoalbys Retirado-Mediaceja, Andrés Adrian Sánchez-Escalona
Publikováno v:
Minería y Geología, Vol 35, Iss 4, Pp 419-429 (2019)
The thermal conductivity of lateritic ores was determined by using the transitory commonly known Hot- Ball method. An experimental facility was built and an experimental design was used for analyzing the property performance for three temperature val
Autor:
Andrés A. Sánchez Escalona, Oscar Miguel Cruz-Fonticiella, Osvaldo García-Morales, Yanán Camaraza-Medina
Publikováno v:
Thermal Science and Engineering Progress. 14:100436
In the present technical note a new method is provided for determining the heat transfer in the fluid flow in single-phase inside rough pipes. The model was tested by adjusting it with existing experimental quantities of a total of 33 different fluid
Publikováno v:
Minería y Geología, Vol 34, Iss 3, Pp 345-359 (2018)
Heat exchangers’ fouling causes increased resistance to thermal exchange, with subsequent efficiency loss. Although related analysis has been exposed in previous studies, the available mathematical models do not consider all forms and mechanisms of
Externí odkaz:
https://doaj.org/article/40c4dea35f76473781e45de973dace7c