Autor:
George Fountos, Anastasios C. Konstantinidis, N. Martini, Dionysios Linardatos, Christos Michail, Ioannis Valais, V. Koukou, Athanasios Bakas
Publikováno v:
Procedia Structural Integrity. 33:304-311
Autor:
N. Martini, Anastasios C. Konstantinidis, George Fountos, V. Koukou, Athanasios Bakas, Dionysios Linardatos, Christos Michail, I. Valais
Publikováno v:
Materials; Volume 14; Issue 4; Pages: 888
Materials
Materials, Vol 14, Iss 888, p 888 (2021)
Materials
Materials, Vol 14, Iss 888, p 888 (2021)
Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd2O2S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized
Publikováno v:
Biomedical Physics & Engineering Express. 7:067004
Quality Control (QC) tests in mammography are very important, since mammograms have been used as a population-based screening test for more than 30 years and QCs lead to better image quality and radiation safety for patients. European guidelines, EUR
Publikováno v:
Radiation Protection Dosimetry. 176:388-399
The aim of this study is to explore the use of a quality (Q) factor in digital mammography as a figure-of-merit. Q factors take a reference value into account and can be compared to a theoretical value. They are also intended to summarise the perform
Autor:
Jerzy Kanicki, Chumin Zhao, Nikita Vassiljev, Anastasios C. Konstantinidis, Robert D. Speller
Publikováno v:
Physics in Medicine and Biology. 62:1994-2017
High-resolution, low-noise x-ray detectors based on the complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been developed and proposed for digital breast tomosynthesis (DBT). In this study, we evaluated the three
Autor:
Dionysios Linardatos, Christos Michail, Athanasios Bakas, Anastasios C. Konstantinidis, Konstantinos Ninos, Ioannis Valais, Nektarios Kalyvas, Ioannis Kandarakis, George Fountos
Publikováno v:
Crystals, Vol 10, Iss 961, p 961 (2020)
Crystals
Volume 10
Issue 11
Crystals
Volume 10
Issue 11
In this study, the light output of a zinc selenide activated with tellurium (ZnSe: Te) single crystal was measured for X-ray radiography applications. A cubic crystal (10 ×
10 ×
10 mm) was irradiated using X-rays with tube voltage
10 ×
10 mm) was irradiated using X-rays with tube voltage
Autor:
K Ricketts, Paul Seller, Hanan Alzahrani, Gary Royle, I. Sedgwick, Anastasios C. Konstantinidis, S. Richards
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 968:163914
The demand for adequate image quality with low radiation doses for patients has greatly increased. This is especially true in the case of position verification in radiotherapy which requires a high number of images per patient. This study presents a
Publikováno v:
Physics in medicine and biology. 64(2)
Medical imaging systems like full field digital mammography (FFDM) and digital breast tomosynthesis (DBT) commonly use amorphous selenium (a-Se) based passive pixel sensor (PPS) direct conversion x-ray detectors. On one hand, direct conversion detect
Autor:
Paul Seller, K Ricketts, Anastasios C. Konstantinidis, S. Richards, Gary Royle, Hanan Alzahrani, I. Sedgwick
Publikováno v:
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).
The demand for adequate image quality with low radiation doses for patients has greatly increased. This is especially true in the case of position verification in radiotherapy which requires a high number of images per patient. This study presents a
Publikováno v:
Medical Physics. 42:6294-6308
Purpose: Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electroni