Zobrazeno 1 - 10
of 37
pro vyhledávání: '"Ana Cecília Diniz Viana"'
Autor:
Suzanny Cristina Soares Martins, Jéssica Dornelas Silva, Ana Cecília Diniz Viana, Vicente Tadeu Lopes Buono, Leandro Arruda Santos
Publikováno v:
Materials Research, Vol 23, Iss 3 (2020)
Heat treatments and geometries have a significant influence on the mechanical behavior of endodontic files. Finite element analyses were performed to verify the effects due to each of these parameters in NiTi files. Two designs and three NiTi atomic
Externí odkaz:
https://doaj.org/article/ab5c2120a9c842ad9a7a75417b37c237
Autor:
Túlio César MODESTO, Eufemia Carolina Peláez ACOSTA, Pedro Damas RESENDE, Érika Sales Joviano PEREIRA, Isabella Faria da Cunha PEIXOTO, Vicente Tadeu Lopes BUONO, Ana Cecília Diniz VIANA
Publikováno v:
Journal of Applied Oral Science, Vol 26, Iss 0 (2018)
Abstract Objective The aim of this study was to evaluate the influence of torsional preloading on the cyclic flexural fatigue resistance of thermally treated NiTi instruments. Material and Methods Ten new instruments New Hyflex CM (HF 30.06; Coltene/
Externí odkaz:
https://doaj.org/article/2f407185d26d430fa564a0793cd116a7
Autor:
Warley Luciano Fonseca Tavares, Ana Cecília Diniz Viana, Marcus Vinícius Lucas Ferreira, Gabriela da Costa Ferreira, Isabella da Costa Ferreira, Ricardo Alves de Mesquita, Rodrigo Rodrigues Amaral
Publikováno v:
Journal of Endodontics.
Autor:
Isabella Figueiredo Assis Macedo, Marcella Mattos Duarte, Hebertt Gonzaga dos Santos Chaves, Barbara Figueiredo, Ana Carolina Trindade Valadares, Ana Cecília Diniz Viana, Christiane Valente Araújo
During endodontic procedures, the occurrence of iatrogenesis can compromise the success of the treatment and knowing how to conduct them is essential for a favorable outcome. Endodontic perforation is a communication between the pulp space and the ex
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e68498957722cf0197b9342556db19d7
https://doi.org/10.56238/colleinternhealthscienv1-096
https://doi.org/10.56238/colleinternhealthscienv1-096
Autor:
Paula Ribeiro Garcia, Leandro de Arruda Santos, Vicente Tadeu Lopes Buono, Suzanny Cristina Soares Martins, Ana Cecília Diniz Viana
Publikováno v:
Journal of Materials Engineering and Performance. 29:2095-2102
The influence of cross-sectional eccentricity on the flexibility, torsional stiffness, and stress distribution in NiTi endodontic files was studied by finite element modeling. Three-dimensional (3D) models were built in order to reproduce commercial
Autor:
Lucas Pinho Simões, Alexandre Henrique dos Reis-Prado, Carlos Roberto Emerenciano Bueno, Ana Cecília Diniz Viana, Marco Antônio Húngaro Duarte, Luciano Tavares Angelo Cintra, Cleidiel Aparecido Araújo Lemos, Francine Benetti
Publikováno v:
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual)
Universidade de São Paulo (USP)
instacron:USP
Universidade de São Paulo (USP)
instacron:USP
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f8304bfa74b45ef54d7213b94640a42f
Autor:
Lucas Pinho, Simões, Alexandre Henrique, Dos Reis-Prado, Carlos Roberto Emerenciano, Bueno, Ana Cecília Diniz, Viana, Marco Antônio Húngaro, Duarte, Luciano Tavares Angelo, Cintra, Cleidiel Aparecido Araújo, Lemos, Francine, Benetti
Publikováno v:
Restorative dentistryendodontics. 47(2)
This systematic review (register-osf.io/wg7ba) compared the efficacy and safety of rotary and reciprocating kinematics in the removal of filling material from curved root canals.OnlyThe search resulted in 2,795 studies, of which 15 were included. Eff
Autor:
Gustavo de Cristofaro Almeida, Pedro Damas Resende, Ana Cecília Diniz Viana, Vicente Tadeu Lopes Buono, L C Guimarães, Isabella Faria da Cunha Peixoto
Publikováno v:
International Endodontic Journal. 52:1768-1772
AIM To compare the martensitic transformation temperatures and torsional resistance behaviour of classic M-Wire Reciproc and Reciproc blue files (VDW, Munich, Germany). METHODOLOGY M-Wire classic Reciproc R25 and Reciproc blue R25 instruments were us
Autor:
Isabella Faria da Cunha Peixoto, Diego Pinheiro Aun, Gustavo de Cristofaro Almeida, Vicente Tadeu Lopes Buono, Maria Guiomar de Azevedo Bahia, Ana Cecília Diniz Viana, Pedro Damas Resende
Publikováno v:
Australian Endodontic Journal. 46:52-59
This study assessed the cutting properties of two Nickel Titanium file systems with different designs and manufacturing materials. ProTaper Next X1 and X2 (PTN; Dentsply Sirona) and ProTaper Universal S2 and F1 (PTU; Dentsply Sirona) instruments were
Autor:
Isabella Figueiredo Assis Macedo, Marcella Mattos Duarte, Hebertt Gonzaga dos Santos Chaves, Barbara Figueiredo, Ana Carolina Trindade Valadares, Ana Cecília Diniz Viana, Christiane Valente Araújo
Publikováno v:
Research, Society and Development. 11:e32511528489
Durante procedimentos endodônticos, a ocorrência de iatrogenias pode comprometer o sucesso do tratamento e saber conduzi-las é essencial para um desfecho favorável. A perfuração endodôntica é uma comunicação, iatrogênica ou patológica, en