Energy and Buildings. 170:122-133
peer-reviewed The full text of this article will not be available in ULIR until the embargo expires on the 17/04/2020 Building energy simulations have found widespread use as decision-making tools for determining design and retrofitting actions. Desp
Publikováno v:
Energy. 147:995-1006
The accuracy of building energy simulations is of considerable interest as discrepant results can elicit adverse financial and environment consequences. The physical and temporal scales considered within building energy applications necessitate compa
Publikováno v:
ACM Transactions on Cyber-Physical Systems. 1:1-25
Commercial buildings are significant consumers of electricity. We propose a number of methods for managing power in commercial buildings. The first step toward better energy management in commercial buildings is monitoring consumption. However, instr
Publikováno v:
Energy. 125:211-222
peer-reviewed Improving building energy efficiency is of paramount importance due to the large proportion of energy consumed by thermal operations. Consequently, simulating a building's environment has gained popularity for assessing thermal comfort
Publikováno v:
Building and Environment. 93:395-405
Data centres consume high levels of energy to power the IT equipment contained within them, and extract the heat they produce. Because of the industry's heavy reliance on power, data centre metrics have historically used operational efficiency as a p
Publikováno v:
The International Journal of Life Cycle Assessment. 20:332-349
Data centres are high-energy consumers, and historical assessment of their environmental impact has focused largely on energy consumption. Widely adopted assessment methods consider either single issues or do not comprehensively assess links between
Publikováno v:
Building and Environment. 82:151-159
Data centres consume high levels of energy to power the IT equipment contained within them, and extract the heat they produce. Because of the industry's heavy reliance on power, data centre metrics have historically used operational efficiency as a p
Publikováno v:
ACM Transactions on Intelligent Systems and Technology. 5:1-21
With increasing public consciousness regarding sustainability, companies are ever more eager to introduce eco-friendly products and services. Assessing environmental footprints and designing sustainable products are challenging tasks since they requi
The chiller cooled data center environment consists of many interlinked elements that are usually treated as individual components. This chain of components and their influences on each other must be considered in determining the benefits of any data
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5a67dd5d849bbf13b558b05a7cdf9d32
https://ora.ox.ac.uk/objects/uuid:a188f2b9-84e0-4c5e-9650-ccc7f307f74c
https://ora.ox.ac.uk/objects/uuid:a188f2b9-84e0-4c5e-9650-ccc7f307f74c
Autor:
Thomas J. Breen, Tahir Cader, Jeff Punch, Amip J. Shah, Niru Kumari, Ed Walsh, Cullen E. Bash
Infrastructure efficiency metrics, such as Power Usage Effectiveness (PUE) and Data Center Infrastructure Efficiency (DCiE), have gained much traction within the industry for evaluating data center energy efficiency. Gradually, however, as the lines
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ea6a6d4f8a4ad1088a899a3aa1b38b15
https://ora.ox.ac.uk/objects/uuid:60550bc4-6454-4a4e-840b-12807ae7a939