Zobrazeno 1 - 10
of 49
pro vyhledávání: '"Amando Gamba"'
Autor:
Giordano Tasca, Jaroslav Lindner, Laurent Barandon, Petr Santavy, Carlo Antona, Jan Burkert, Amando Gamba
Publikováno v:
Journal of Cardiothoracic Surgery, Vol 14, Iss 1, Pp 1-6 (2019)
Abstract Background Sparing Aortic Valve procedure requires to reproduction of the geometry of the physiologic anatomy of the aortic root. Thus, the materials adopted may make a difference. CARDIOROOT is a one-piece collagen-coated woven vascular gra
Externí odkaz:
https://doaj.org/article/cd12921bbf184b91b3fee83013d3c41d
Publikováno v:
Case Reports in Surgery, Vol 2017 (2017)
Mediastinal radiation is commonly used to treat Hodgkin’s and non-Hodgkin’s lymphoma, lung and breast cancer. Cardiac complications after radiation therapy are well described, although rare. A large spectrum of injuries can occur, causing long te
Externí odkaz:
https://doaj.org/article/2764549b9d3a491e81c9e7b60238ed0a
Autor:
Andrea Nasatti, Giordano Tasca, Elisabetta Lobiati, Amando Gamba, Francesco Trinca, Beatrice Riva, Paolo Faccioli
Publikováno v:
The Journal of Cardiovascular Surgery. 61
Background Patients with aortic root ectasia and bicuspid aortic valve benefit of the treatment with aortic valve sparing procedure, with excellent long-term results. The Sleeve-procedure is one of the options in patients with aortic root diseases an
Autor:
Amando Gamba, Petr Santavy, Giordano Tasca, Laurent Barandon, Carlo Antona, Jaroslav Lindner, Jan Burkert
Publikováno v:
Journal of Cardiothoracic Surgery, Vol 14, Iss 1, Pp 1-6 (2019)
Journal of Cardiothoracic Surgery
Journal of Cardiothoracic Surgery
Background Sparing Aortic Valve procedure requires to reproduction of the geometry of the physiologic anatomy of the aortic root. Thus, the materials adopted may make a difference. CARDIOROOT is a one-piece collagen-coated woven vascular graft with p
Aortic Root Dynamics in Sleeve Aortic Sparing Procedure: Echocardiographic and Computational Studies
Autor:
Emiliano Votta, Alberto Redaelli, Beatrice Riva, Giordano Tasca, Elisabetta Lobiati, Amando Gamba, Matteo Selmi
In Sleeve procedure, the leaflets-sinus unit is maintained. We hypothesized that this feature partially preserves aortic root (AR) dynamics and leaflets kinematics and limits tensions in the leaflets. We tested our hypothesis based on in vivo and com
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1a5edff181050d4e3b0ca5a8e4f5e782
http://hdl.handle.net/11311/1121231
http://hdl.handle.net/11311/1121231
Autor:
Amando Gamba, Alberto Redaelli, Riccardo Vismara, Paola Redaelli, Gianfranco Beniamino Fiore, Giordano Tasca, Carlo Antona, Claudia Romagnoni
Hydrodynamic performance of stented bioprostheses is far below that of the native valve. One of the reasons is that the internal diameter of the prosthesis is usually smaller than that of the native valve. However, other valve characteristics are als
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1f096a03f027537688fe8b529aeab4f4
http://hdl.handle.net/11311/1045513
http://hdl.handle.net/11311/1045513
Autor:
Beatrice Riva, Elisabetta Lobiati, Amando Gamba, Francesco Trinca, Riccardo Vismara, Giordano Tasca
Publikováno v:
Journal of cardiac surgery. 32(11)
Background Stentless valves have long been considered the ideal valves in terms of hemodynamics. Recently, the Trifecta valve, a stented bioprosthesis with excellent fluid dynamic characteristics, has become available. The aim of the study was to com
Autor:
Andrea Galanti, Douglas Skouse, Floriana Giannico, Elisabetta Lobiati, Amando Gamba, Michele Triggiani, Antonello Stefano Martino, Giordano Tasca
Publikováno v:
The Annals of Thoracic Surgery. 99:1228-1233
Background The aim of this retrospective study was to evaluate our experience of using a simplified aortic valve sleeve procedure to treat aortic root ectasia and aneurysms with or without aortic regurgitation. In experienced hands, 2 aortic valve-sp
Autor:
Beatrice Riva, Caterina Chiara De Carlini, Elisabetta Lobiati, Amando Gamba, Paola Redaelli, Giordano Tasca
Publikováno v:
Journal of Cardiac Surgery. 30:400-404
Background Patients with a small aortic annulus, that is ≤23 mm, constitute a challenge for the surgeon, because they are at high risk of patient-prosthesis mismatch. Stentless valves provide better hemodynamic performance at rest and during exerci
Autor:
Alberto Redaelli, Claudia Romagnoni, Riccardo Vismara, Giordano Tasca, Carlo Antona, Gianfranco Beniamino Fiore, Amando Gamba
Publikováno v:
The Journal of Thoracic and Cardiovascular Surgery. 149:912-918
Background The in vivo hemodynamic performance of a bioprosthesis implanted in an aortic position is affected by the characteristics of the prosthesis and the sizing strategy adopted. Recently, it has been hypothesized that the type of suture used to