Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Allen R. Geiger"'
Publikováno v:
International Journal of High Speed Electronics and Systems. 18:483-492
A compact high peak power eye-safer optical parametric oscillator was constructed by pumping it with a master oscillator power amplifier consisting of a large-mode-area ytterbium doped fiber amplifier and a diode-pumped, passively Q-switched Nd : YAG
Publikováno v:
Fiber Lasers IV: Technology, Systems, and Applications.
We report on an electronically tunable continuous-wave (CW) Ytterbium doped polarization maintaining fiber laser with more than 100 nm tuning range and more than 10 W linearly polarized single spatial mode laser output. The laser can be continuously
Publikováno v:
SPIE Proceedings.
Free-space laser communication has been demonstrated with application potential in many areas such as line-of-sight communications, satellite communications and the last mile solution in a fiber optics networking. Both 0.8 and 1.5 micron wavelengths
Autor:
S. Narasimha Prasad, Allen R. Geiger
Publikováno v:
Advanced Solid State Lasers.
OPOs pumped external to the laser cavity suffer from inefficiencies due to phase distortions and optical losses caused by various intervening optical components and the single pass nature of the pump laser. The internal cavity OPO has the advantage o
Publikováno v:
Remote Sensing of Clouds and the Atmosphere VII.
We report the progress in the development of a compact mid-infrared differential absorption lidar (DIAL) for ground-based and airborne monitoring of leaks in natural gas pipeline systems. This sensor, named Lidar II, weighs approximately 30 kg (70 lb
Publikováno v:
SPIE Proceedings.
LaSen, Inc. is continuing development of compact and rugged lidar systems for ground-based and airborne detection of volatile organic components (VOC) in the mid-infrared spectral region. The first-generation ground-based sensor (Lidar I) measures 0.
Autor:
David F. Schaack, Allen R. Geiger
Publikováno v:
SPIE Proceedings.
One of the limits to the sensitivity of differential absorption lidar (DIAL) when using a topographic reflector is the spectralvariation of the reflectance of the topography (differential albedo). This is especially a problem when DIAL is attemptedfr
Publikováno v:
SPIE Proceedings.
A compact (2'6' X 2'5' X 1'1') 3.30 - 3.47-micrometers DIAL lidar has been constructed for base remediation and chemical monitoring. The lidar system is designed for short range (0.5 km maximum) aerosol backscatter detection of light hydrocarbons wit
Publikováno v:
SPIE Proceedings.
Differential absorption lidars (DIAL) in the mid-infrared (2 - 5 micrometers ) are used to monitor various chemical species. Two wavelengths are required to perform the differential absorption measurement: an `on' line and an `off' line. Previously,