Zobrazeno 1 - 10
of 39
pro vyhledávání: '"Ali Akbar Abdoos"'
Publikováno v:
Journal of Renewable Energy and Environment, Vol 9, Iss 4, Pp 109-121 (2022)
Nowadays, the Permanent Magnet (PM) generator has become an instrumental tool for wind power generation due to its high performance. In this study, an optimal design is established to provide a cost-effective multiphase outer-rotor PM wind generator
Externí odkaz:
https://doaj.org/article/c408e5466ba742a186b9003b40053fbb
Publikováno v:
Energy. :127914
Autor:
Mohammad Mehdi Mobashsher, Ali Akbar Abdoos, Seyyed Mehdi Hosseini, Sayyed Mohammad Hashemi, Majid Sanaye-Pasand
Publikováno v:
International Journal of Electrical Power & Energy Systems. 147:108793
Publikováno v:
Periodica Polytechnica Electrical Engineering and Computer Science. 65:53-61
The Current Transformers (CT) saturation may cause the protective relays mal-operation either non-recognition of internal fault or undesirable trip under external fault conditions. Therefore, compensation of CT saturation is very important for correc
Publikováno v:
Electric Power Systems Research. 216:109054
Publikováno v:
Engineering Reports, Vol 3, Iss 12, Pp n/a-n/a (2021)
In power systems, busbars connect important components such as generators, transmission lines, and loads. A typical fault occurrence on the busbar may result in the isolation of faulty sections from other normally operating parts of the system result
Autor:
Claus Leth Bak, Mani Ashouri, Filipe Miguel Faria da Silva, Seyed Mehdi Hosseini, Ali Akbar Abdoos
Publikováno v:
Ashouri, M, Da Silva, F F, Bak, C L, Abdoos, A & Hosseini, S M 2020, ' Modal online differential fault detection and localisation scheme for VSC-MTDC cable transmission ', IET Generation, Transmission & Distribution, vol. 14, no. 20, pp. 4475-4487 . https://doi.org/10.1049/iet-gtd.2020.0437
This study proposes a modal online differential fault detection and localization (MODF) scheme for VSC-MTDC cable transmission. Modal theory is used to remove the coupling between layers of two-core extruded high-voltage direct current cable. As a re
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::29075593ae5e9e483c57d56e6483dd6e
https://vbn.aau.dk/da/publications/a626784b-0a9f-4553-8413-7bf759c17ae6
https://vbn.aau.dk/da/publications/a626784b-0a9f-4553-8413-7bf759c17ae6
Autor:
Amir Hossein Azimi, Ali Akbar Abdoos
Publikováno v:
Technology and Economics of Smart Grids and Sustainable Energy. 5
In many countries, the parallel lines are widely used in transmission systems due to economic and technical benefits. Distance relays have poor performance on the protection of parallel transmission lines because of the mutual coupling effect. The di