Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Alexia L Saunders"'
Autor:
David A X Nayagam, Richard A Williams, Penelope J Allen, Mohit N Shivdasani, Chi D Luu, Cesar M Salinas-LaRosa, Sue Finch, Lauren N Ayton, Alexia L Saunders, Michelle McPhedran, Ceara McGowan, Joel Villalobos, James B Fallon, Andrew K Wise, Jonathan Yeoh, Jin Xu, Helen Feng, Rodney Millard, Melanie McWade, Patrick C Thien, Chris E Williams, Robert K Shepherd
Publikováno v:
PLoS ONE, Vol 9, Iss 5, p e97182 (2014)
To assess the safety and efficacy of chronic electrical stimulation of the retina with a suprachoroidal visual prosthesis.Seven normally-sighted feline subjects were implanted for 96-143 days with a suprachoroidal electrode array and six were chronic
Externí odkaz:
https://doaj.org/article/9eed3a29f32240d3a09b8968ea2f0b71
Autor:
Nicholas L. Opie, Jonathan Yeoh, Mohit N. Shivdasani, Mihailo Evans, Joel Villalobos, Robert K. Shepherd, Ceara McGowan, Lisa Cardamone, Anu Sabu, Hamish Meffin, Alexia L. Saunders, Rosemary Cicione, Penelope J Allen, Steven Prawer, Michelle McPhedran, Chi D Luu, Richard A. Williams, Arman Ahnood, Owen Burns, Kate Fox, Chris E. Williams, Anthony N. Burkitt, Carla J Abbott, Vanessa Maxim, David J. Garrett, Kumaravelu Ganesan, David A X Nayagam
Publikováno v:
Journal of Neural Engineering. 17:045014
OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo perfor
Autor:
Kumaravelu Ganesan, Samantha Lichter, Alexia L. Saunders, David J. Garrett, Hamish Meffin, Steven Prawer, Mathilde Escudie, Alastair Stacey, Owen Burns, David A X Nayagam, Aaron Z. Lee, Ceara McGowan, Nicholas V. Apollo, Richard A. Williams, Dunstan C. Kua, Arman Ahnood, Kate Fox
Publikováno v:
Biomaterials. 53:464-474
As the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems s
Autor:
Richard A. Williams, Hamish Meffin, Kumaravelu Ganesan, David A X Nayagam, Alexia L. Saunders, Ceara McGowan, David J. Garrett, Joscha Specks
Publikováno v:
Journal of Biomedical Materials Research Part B: Applied Biomaterials. 104:19-26
Recently, there has been interest in investigating diamond as a material for use in biomedical implants. Diamond can be rendered electrically conducting by doping with boron or nitrogen. This has led to inclusion of boron doped and nitrogen included
Autor:
Ronald T. Leung, Richard A. Williams, Cesar M. Salinas-La Rosa, David A X Nayagam, Jonathan Yeoh, Alexia L. Saunders, Meri Basa, Mohit N. Shivdasani, Robert K. Shepherd, Chris E. Williams, Chi D Luu, Penelope J Allen, Lauren N Ayton
Publikováno v:
Clinical & Experimental Ophthalmology. 43:247-258
Background A key requirement for retinal prostheses is the ability for safe removal or replacement. We examined whether suprachoroidal electrode arrays can be removed or replaced after implantation. Methods Suprachoroidal electrode arrays were unilat
Autor:
Kate, Fox, Hamish, Meffin, Owen, Burns, Carla J, Abbott, Penelope J, Allen, Nicholas L, Opie, Ceara, McGowan, Jonathan, Yeoh, Arman, Ahnood, Chi D, Luu, Rosemary, Cicione, Alexia L, Saunders, Michelle, McPhedran, Lisa, Cardamone, Joel, Villalobos, David J, Garrett, David A X, Nayagam, Nicholas V, Apollo, Kumaravelu, Ganesan, Mohit N, Shivdasani, Alastair, Stacey, Mathilde, Escudie, Samantha, Lichter, Robert K, Shepherd, Steven, Prawer
Publikováno v:
Artificial organs. 40(3)
Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause re
Autor:
Chris E. Williams, Michelle McPhedran, Jin Xu, Penelope J Allen, Jonathan Yeoh, Mohit N. Shivdasani, Lauren N Ayton, Richard A. Williams, Sue Finch, Robert K. Shepherd, Patrick C. Thien, Alexia L. Saunders, Ceara McGowan, David A X Nayagam, Andrew K. Wise, James B Fallon, Cesar M. Salinas-LaRosa, Helen Feng, Melanie A. McWade, Rodney E. Millard, Chi D Luu, Joel Villalobos
Publikováno v:
PLoS ONE
PLoS ONE, Vol 9, Iss 5, p e97182 (2014)
PLoS ONE, Vol 9, Iss 5, p e97182 (2014)
Purpose To assess the safety and efficacy of chronic electrical stimulation of the retina with a suprachoroidal visual prosthesis. Methods Seven normally-sighted feline subjects were implanted for 96–143 days with a suprachoroidal electrode array a
Autor:
Ronald T, Leung, David A X, Nayagam, Richard A, Williams, Penelope J, Allen, Cesar M, Salinas-La Rosa, Chi D, Luu, Mohit N, Shivdasani, Lauren N, Ayton, Meri, Basa, Jonathan, Yeoh, Alexia L, Saunders, Robert K, Shepherd, Chris E, Williams
Publikováno v:
Clinicalexperimental ophthalmology. 43(3)
A key requirement for retinal prostheses is the ability for safe removal or replacement. We examined whether suprachoroidal electrode arrays can be removed or replaced after implantation.Suprachoroidal electrode arrays were unilaterally implanted int
Autor:
Alexia L. Saunders, Owen Burns, Michelle McPhedran, Nicholas L. Opie, Lauren N Ayton, Chris E. Williams, Penelope J Allen, Jonthan Yeoh, Mark McCombe, Robyn H. Guymer, David A X Nayagam, Wilson J. Heriot, Robert Briggs, Robert K. Shepherd, Ceara McGowan, Joel Villalobos, Chi D Luu
Publikováno v:
Clinicalexperimental ophthalmology. 42(7)
Background Current surgical techniques for retinal prosthetic implantation require long and complicated surgery, which can increase the risk of complications and adverse outcomes. Method The suprachoroidal position is known to be an easier location t
Autor:
Fox, Kate1,2, Meffin, Hamish3,4, Burns, Owen5, Abbott, Carla J.6, Allen, Penelope J.6, Opie, Nicholas L.6, McGowan, Ceara5, Yeoh, Jonathan6, Ahnood, Arman1, Luu, Chi D.6, Cicione, Rosemary1, Saunders, Alexia L.5, McPhedran, Michelle5, Cardamone, Lisa5, Villalobos, Joel5, Garrett, David J.1,5, Nayagam, David A. X.5, Apollo, Nicholas V.1,5, Ganesan, Kumaravelu1, Shivdasani, Mohit N.5
Publikováno v:
Artificial Organs. Mar2016, Vol. 40 Issue 3, pE12-E24. 13p.