Zobrazeno 1 - 10
of 31
pro vyhledávání: '"Alexandre M Caraça, Santos"'
Publikováno v:
ACS Applied Nano Materials. 4:7471-7478
Publikováno v:
Physical and Engineering Sciences in Medicine. 44:457-471
The fabrication of brachytherapy surface moulds is considered laborious and time consuming that often result in repeated attempts due to incorrect catheter positioning or the presence of air gaps. 3-dimensional printing using low-cost and reliable ma
Publikováno v:
Acta Oncologica. 60:300-304
Background and purpose: Proton therapy has been proposed as a technique to improve the long-term quality of life of breast cancer patients. This is due to its ability to reduce the dose to healthy tissue compared to conventional X-ray therapy. The ai
In this study, we investigate whether an acceptable dosimetric plan can be obtained for a surface applicator designed using photogrammetry and compare the plan quality to a CT-derived applicator. The nose region of a RANDO anthropomorphic phantom was
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::32a84e86484e16cc78b7f9440ed8d61a
https://doi.org/10.21203/rs.3.rs-937351/v1
https://doi.org/10.21203/rs.3.rs-937351/v1
Publikováno v:
Physical and engineering sciences in medicine. 45(1)
In this study, we investigate whether an acceptable dosimetric plan can be obtained for a brachytherapy surface applicator designed using photogrammetry and compare the plan quality to a CT-derived applicator. The nose region of a RANDO anthropomorph
Publikováno v:
Physica Medica. 65:15-20
An investigation into the response of optical fibres to 16.5 MeV protons is presented here. A silica and a poly(methyl methacrylate) (PMMA) optical fibre was exposed to 16.5 MeV protons from a GE PETtrace cyclotron.The optical fibres were exposed to
Publikováno v:
Brachytherapy. 18:689-700
Purpose We propose a novel method of designing surface mold brachytherapy applicators using optical photogrammetry. The accuracy of this technique for the purpose of 3D-printing surface mold brachytherapy applicators is investigated. Methods and Mate
Publikováno v:
Australasian Physical & Engineering Sciences in Medicine. 42:863-869
Respiratory gated treatments are now common in order to reduce tumour motion uncertainties due to breathing. One issue associated with gated treatments is the time delay between the gating system and the linear accelerator. In this study we develop a
Autor:
Alexandre M. Caraça Santos, Heike Ebendorff-Heidepriem, Nigel A. Spooner, David J. Ottaway, Christopher A. G. Kalnins, Carly A. Whittaker
Publikováno v:
Radiation Measurements. 122:57-62
Plastic scintillation detectors (PSDs) have been extensively tested as in-vivo dosimeters for brachytherapy dosimetry, but they are known to suffer from an energy dependence in low energy photon beams, an unwanted characteristic of any dosimeter. It
Publikováno v:
Nanotechnology. 32(40)
Owing to many fascinating properties including high thermal and chemical stability, excellent electrical insulation, fire-retardant and antibacterial properties, hexagonal boron nitride (hBN) has emerged as a prominent 2D material for broad applicati