Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Alexander Bohnhorst"'
Autor:
Florian Schlottmann, Christoph Schaefer, Ansgar T. Kirk, Alexander Bohnhorst, Stefan Zimmermann
Publikováno v:
Journal of the American Society for Mass Spectrometry. 34:893-904
Publikováno v:
tm - Technisches Messen. 89:847-858
Low-noise current meters are usually designed using high value feedback resistors. However, a high resistance reduces the maximum measurable current at a given output voltage and the maximum bandwidth at a given parasitic capacitance. Capacitive tran
Publikováno v:
Analytical Chemistry 95 (2023), Nr. 18
Analytical Chemistry
Analytical Chemistry
In this work, we present a tandem ion mobility spectrometer (IMS) utilizing a highly efficient ion manipulator allowing to store, manipulate, and analyze ions under high electric field strengths and controlled ion-neutral reactions at ambient conditi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::998172e06d9f41f23bb84ffcf4e75cfe
https://www.repo.uni-hannover.de/handle/123456789/14247
https://www.repo.uni-hannover.de/handle/123456789/14247
Publikováno v:
Analytical Chemistry. 93:6062-6070
Printed circuit board (PCB) based drift tube ion mobility spectrometers enable the use of state-of-the-art production techniques to manufacture compact devices with excellent performance at minimum cost. The new PCB ion mobility spectrometer (PCB-IMS
Publikováno v:
tm - Technisches Messen. 88:262-273
While the resolving power of drift tube ion mobility spectrometers has been studied and modelled in detail over the past decades, no comparable model exists for the signal-to-noise-ratio. In this work, we develop an analytical model for the signal-to
Publikováno v:
Journal of the American Society for Mass Spectrometry : JASMS online 31 (2020), Nr. 7
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) are usually operated at an absolute pressure of 20 mbar reaching high reduced electric field strengths of up to 125 Td for controlled reaction kinetics. This significantly increases the linear
Autor:
Alexander Bohnhorst, Martin Lippmann, Maximilian J. Kueddelsmann, Ansgar T. Kirk, Stefan Zimmermann
Publikováno v:
Analytical Chemistry. 92:4838-4847
Field switching ion shutters allow generating short ion packets with high ion densities by first ionizing for several milliseconds in a field-free ionization region and then quickly pushing the entire ion population out into the drift region. Thus, t
Publikováno v:
Analytical chemistry. 94(2)
Ion mobility spectrometers (IMS) are well suited for detecting trace gases down to levels at ppb
Publikováno v:
Analytical Chemistry. 91:8941-8947
Collision induced dissociation (CID) is a widely used technique in mass spectrometry to better understand the structural composition of ions and to improve the identification of compounds beyond the analysis of
Publikováno v:
Journal of the American Society for Mass Spectrometry. 30:1813-1823
Ion funnels are one of the key components for transferring ions from higher pressure into the vacuum. Typically, ion funnels are constructed of several different plate ring electrodes with a decreasing inner diameter where radio frequency (RF) voltag