Zobrazeno 1 - 10
of 51
pro vyhledávání: '"Alexander, Giurea"'
Autor:
Thomas M Grupp, Sabine Rusch, Philippe Massin, Ashley Blom, Eduardo Garcia-Rey, Luca Cristofolini, Dennis Janssen, Bernd Grimm, Alexander Giurea, Marcus Jäger, Francesco Siccardi, Søren Overgaard
Publikováno v:
EFORT Open Reviews, Vol 8, Iss 7, Pp 499-508 (2023)
The objectives of the 1st EFORT European Consensus on ‘Medical and Scientific Research Requirements for the Clinical Introduction of Artificial Joint Arthroplasty Devices’ were foremost to focus on patient safety by establishing performance requi
Externí odkaz:
https://doaj.org/article/f3d34a1861a94246b1db378693c9ee44
Autor:
Klemens Vertesich, Kevin Staats, Christoph Böhler, Richard Koza, Richard Lass, Alexander Giurea
Publikováno v:
Frontiers in Bioengineering and Biotechnology, Vol 10 (2022)
Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication typ
Externí odkaz:
https://doaj.org/article/281941fdadae4f24a78ae834b27c3f07
Publikováno v:
Applied Sciences, Vol 11, Iss 21, p 10322 (2021)
Although simulation models are heavily used in biomechanical research and testing of TKA implants, pre-clinical tools for a holistic estimation of implant performance under dynamic loading conditions are rare. The objective of this study was the deve
Externí odkaz:
https://doaj.org/article/8ffd8c58002b423e894eb5478e93c709
Autor:
Beate M. Rüger, Tanja Buchacher, Alexander Giurea, Bernd Kubista, Michael B. Fischer, Johannes M. Breuss
Publikováno v:
Frontiers in Physiology, Vol 9 (2018)
Introduction: New vessel formation requires a continuous and tightly regulated interplay between endothelial cells with cells of the perivascular microenvironment supported by mechanic-physical and chemical cues from the extracellular matrix.Aim: Her
Externí odkaz:
https://doaj.org/article/1e832adfc35b4d76aab479968078758b
Autor:
Reinhard Windhager, Johannes Holinka, Florian Sevelda, Richard Lass, Alexander Giurea, Irene K. Sigmund, Kevin Staats, Bernd Kubista
Publikováno v:
International Orthopaedics
Purpose Besides other diagnostic test methods, established serum inflammatory markers such as serum C-reactive protein or leukocyte count are widely used preoperatively to aid in diagnosing periprosthetic joint infections (PJI). Although low accuraci
Autor:
Elisabeth M. Sporer, Christoph Schilling, Adrian Sauer, Robert J. Tait, Alexander Giurea, Thomas M. Grupp
Publikováno v:
BioMed Research International.
End-of-stem pain of the femur is a common problem in revision total knee arthroplasty (TKA). It may be caused by a problematic interaction between stem and bone, but the exact biomechanical correlate is still unknown. The aim of this prospective stud
Autor:
Klemens Vertesich, Kevin Staats, Christoph Böhler, Richard Koza, Richard Lass, Alexander Giurea
Publikováno v:
Frontiers in bioengineering and biotechnology. 10
Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication typ
Publikováno v:
Applied Sciences, Vol 11, Iss 10322, p 10322 (2021)
Applied Sciences
Volume 11
Issue 21
Applied Sciences
Volume 11
Issue 21
Although simulation models are heavily used in biomechanical research and testing of TKA implants, pre-clinical tools for a holistic estimation of implant performance under dynamic loading conditions are rare. The objective of this study was the deve
No effect in primary stability after increasing interference fit in cementless TKA tibial components
Autor:
Esther Sánchez, Thomas M. Grupp, Dennis Janssen, Nico Verdonschot, Christoph Schilling, Alexander Giurea
Publikováno v:
Journal of the Mechanical Behavior of Biomedical Materials, 118
Journal of the mechanical behavior of biomedical materials, 118:104435. Elsevier
Journal of the mechanical behavior of biomedical materials, 118:104435. Elsevier
Cementless total knee arthroplasty (TKA) implants rely on interference fit to achieve initial stability. However, the optimal interference fit is unknown. This study investigates the effect of using different interference fit on the initial stability
Autor:
Anita Fischer, Reinhard Windhager, Daniela Weinmann, Friedrich Altmann, Stefan Toegel, Hans-Joachim Gabius, Katharina M. Pichler, Johannes Fuehrer, Alexander Giurea
Publikováno v:
Proteomics. Clinical Applications
Purpose N-Glycan profiling provides an indicator of the cellular potential for functional pairing with tissue lectins. Following the discovery of galectin expression by chondrocytes as a factor in osteoarthritis pathobiology, mapping of N-glycans upo