Zobrazeno 1 - 10
of 37
pro vyhledávání: '"Alan H Cookson"'
Autor:
Ralph Samm, Arend van Roggen, Gian Carlo Montanari, Armin Bruning, Bruce S. Bernstein, Alan H. Cookson, Matthew Mashikian, John Tanaka, C. W. Reed, Ray Bartnikas
Publikováno v:
IEEE Electrical Insulation Magazine. 25:40-43
Autor:
O. L. Mayorga, Charles J. Newbold, Michael K. Theodorou, Sharon Huws, Alan H Cookson, Eun Joong Kim, Alison H. Kingston-Smith
Publikováno v:
Journal of Microbial & Biochemical Technology.
In this experiment we investigated the hypothesis that heterogeneity of plant structures presents disparity in niches available for colonisation by the rumen microbiota resulting in differential colonisation. Fresh perennial ryegrass (PRG) stem and l
Publikováno v:
IEEE Electrical Insulation Magazine. 30:52-52
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :400-409
An SF6 insilated semi-flexible transmiission line is described which uses a corrugated aluminum enclosure to reduce cost and provide flexibility. Dielectric characteristics of a compact 1200 kV design (711mm (28 in) internal diameter enclosure) with
A Test for the Effect of High Energy Arcs on the Flash-over Strength of Insulators in Compressed SF6
Publikováno v:
IEEE Transactions on Electrical Insulation. :74-80
A test method for evaluation of solid insulating material for insulators in Compressed Gas Insulated Transmission (CGIT) systems has been developed. The test measures the ability of an insulating surface to withstand voltage after being subjected to
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. 96:768-777
High-voltage breakdown measurements were made in two similar particle contaminated coaxial test systems, one with AC and the other with DC voltages. Information is presented on the effects of particle size, shape, and material for both SF 6 and N 2 g
Autor:
Alan H. Cookson, Chathan M. Cooke
Publikováno v:
IEEE Transactions on Electrical Insulation. :239-248
The gaseous state of matter is an excellent high voltage insulator which nonetheless is subject to overstresses and electrical breakdown. The main parameters which govern insulation strength in gases are identified as gas density and time duration of
Autor:
Alan H. Cookson, Roy E. Wootton
Publikováno v:
IEEE Transactions on Power Apparatus and Systems. :415-423
The ac corona onset and breakdown voltages have been measured for rod-plane and rod-rod gaps in hydrogen, SF6, and hydrogen-SF6 mixtures for pressures between 1 and 5 bar, with gaps up to 14 cm, and voltages up to 250 kV rms. The addition to hydrogen
Autor:
Alan H. Cookson
Publikováno v:
IEEE Transactions on Electrical Insulation. :859-890
Compressed-gas insulated transmission lines or cables have been in service since 1968, with over 13 km (circuit length) in operation worldwide at voltages from 145 to 550 kV. The design philosophy and development are reviewed for the "rigid", flexibl